Conclusions
sHLA-G assayed in amniotic fluid might be a potential indicator of placental function, whereas the sHLA-G level in serum can be a prognostic factor for feto-placental insufficiency.
Methods
sHLA-G in serum and amniotic fluid, as well as fetal biometric data and placental volume and perfusion indices, were determined in 41 singleton pregnancies with no complications. The level of sHLA-G (U/mL) was tested with a sandwich enzyme-linked immunosorbent assay (ELISA) kit.
Results
The sHLA-G levels were unchanged both in amniotic fluid and serum during mid-pregnancy. The sHLA-G level in serum correlated positively with amniotic sHLA-G level (β = 0.63, p < 0.01). Serum sHLA-G level was significantly correlated with abdominal measurements (β = 0.41, p < 0.05) and estimated fetal weight (β = 0.41, p < 0.05). Conversely, amniotic sHLA-G level and placental perfusion (VI: β = -0.34, p < 0.01 and VFI: β = -0.44, p < 0.01, respectively) were negatively correlated. A low amniotic sHLA-G level was significantly associated with nuchal translucency (r = -0.102, p < 0.05). Conclusions: sHLA-G assayed in amniotic fluid might be a potential indicator of placental function, whereas the sHLA-G level in serum can be a prognostic factor for feto-placental insufficiency.