A novel, high-sensitivity and drug-tolerant sandwich immunoassay for the quantitative measurement of circulating proteins

一种用于定量测量循环蛋白的新型高灵敏度和耐药夹心免疫测定法

阅读:4
作者:John H Sloan, Bradley L Ackermann, John W Carpenter, Huy T Nguyen, Kimberly Stopa, Robert W Siegel, Robert J Konrad

Background

Accurate measurement of a total protein target (free plus bound) is essential to optimize dose selection for monoclonal antibody drugs. Herein, we describe a novel sandwich immunoassay format in which the biotherapeutic antibody itself serves as the primary detection antibody. A signal is then generated through the addition of a labeled secondary antibody that recognizes the biotherapeutic antibody. The secondary antibody is conjugated with ruthenium to facilitate electrochemiluminescent analysis.

Conclusion

Our novel format allows drug-tolerant measurement of soluble protein biomarkers targeted by monoclonal antibodies when only two independent epitopes for antibody binding are available and one is recognized by the therapeutic antibody.

Results

Data are presented from the analysis of two protein biomarkers having disparate size and structure; a 4.5 kDa peptide and a 60 kDa protein. In both cases, validated, highly specific assays were developed and shown to be tolerant to elevated levels of the therapeutic monoclonal antibody in question.