Flocked nasal swab versus nasopharyngeal aspirate for detection of respiratory tract viruses in immunocompromised adults: a matched comparative study

植绒鼻拭子与鼻咽抽吸物在免疫功能低下成人中检测呼吸道病毒的效果对比:一项匹配比较研究

阅读:7
作者:Lars Ohrmalm, Michelle Wong, Maria Rotzén-Östlund, Oscar Norbeck, Kristina Broliden, Thomas Tolfvenstam

Background

Several studies have compared nasal swabs to the more invasive nasopharyngeal aspirate (NPA) for detection of respiratory viruses. Mostly, the comparisons have been performed on immunocompetent children with upper respiratory tract symptoms. The

Conclusion

We found the overall sensitivity of 65% to be too low to replace NPA with this sampling technique in this patient category.

Methods

During 16 months, adults with a hematological disorder presenting with febrile neutropenia were enrolled in the study. Paired samples of the fNS and NPA were collected in the outer part of the nasal cavity and the nasopharynx, respectively. The samples were analyzed regarding a panel of 15 respiratory viruses by means of quantitative polymerase chain reaction. Furthermore, as an indirect measure of cell yield by either method, the copy number of the human beta actin gene was also determined. Cohen's kappa was calculated as a measure of agreement of the

Results

A total of 98 paired samples from a total of 89 patients were collected. Twenty of the pairs had virus detected in at least one of the specimens; 11 in both, 7 in NPA only, and 2 in fNS only. For the fNS, the overall sensitivity for any virus and for rhinovirus only was 65% and 78%, respectively. NPA was significantly superior to the fNS in collecting epithelial cells.