Nationwide external quality assessment of SARS-CoV-2 nucleic acid amplification tests in Japan

日本全国范围内 SARS-CoV-2 核酸扩增检测外部质量评估

阅读:8
作者:Satomi Asai, Akira Seki, Yasumasa Akai, Hiromitsu Tazawa, Hidehumi Kakizoe, Mend-Amar Ravzanaaadii, Hayato Miyachi

Conclusions

Performance was mostly dependent on the laboratory category and assay evaluation, particularly the LOD. Guidance should be developed based on these results, particularly in the phase of new entry into laboratory services for SARS-CoV-2.

Methods

A total of 563 public health and private sector laboratories participated. The EQA samples comprised 6 RNA and full-process controls.

Results

The overall agreements were 99.3% and 97.9% for the RNA and full-process controls, respectively. A total of 530/563 (94.1%) laboratories reported correct results; public health laboratories had the highest accuracy. Thirty-three laboratories reported at least one incorrect result (26 laboratories of medical facilities, 5 commercial laboratories, 1 public health laboratory, and 1 other). Sixteen laboratories of medical facilities that used a fully automated assay system failed to detect the presence of the full-process control, due to inherent insufficiency in the limit of detection (LOD). Other causes of incorrect results included failure to ensure the LOD (n = 13), error in result judging or reporting (n = 3), and error in sample handling (n = 1). Conclusions: Performance was mostly dependent on the laboratory category and assay evaluation, particularly the LOD. Guidance should be developed based on these results, particularly in the phase of new entry into laboratory services for SARS-CoV-2.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。