Development of a highly sensitive chemiluminescence immunoassay using a novel signal-enhanced detection system for quantitation of durvalumab, an immune-checkpoint inhibitor monoclonal antibody used for immunotherapy of lung cancer

开发一种高灵敏度化学发光免疫分析法,使用新型信号增强检测系统对用于肺癌免疫治疗的免疫检查点抑制剂单克隆抗体 durvalumab 进行定量分析

阅读:5
作者:Ibrahim A Darwish, Nourah Z Alzoman, Nehal N Y Khalil, Hany W Darwish

Abstract

Durvalumab (DUR) is a human monoclonal antibody used for the immunotherapy of lung cancer. It is a novel immune-checkpoint inhibitor, which blocks the programmed death 1 (PD-1) and programmed death-ligand 1 (PD-L1) proteins and works to promote the normal immune responses that attack the tumour cells. To support the pharmacokinetic (PK) studies, therapeutic drug monitoring (TDM) and refining the safety profile of DUR, an efficient assay is required, preferably immunoassay. This study describes, for the first time, the development of a highly sensitive chemiluminescence immunoassay (CLIA) for the quantitation of DUR in plasma samples with enhanced chemiluminescence detection system. The CLIA protocol was conducted in 96-microwell plates and involved the non-competitive binding reaction of DUR to its specific antigen (PD-L1 protein). The immune complex of DUR with PD-L1 formed onto the inner surface of the assay plate wells was quantified by a chemiluminescence (CL)-producing horseradish peroxidase (HRP) reaction. The reaction employed 4-(1,2,4-triazol-1-yl)phenol (TRP) as an efficient enhancer of the HRP-luminol-hydrogen peroxide (H2O2) CL reaction. The optimum protocol of the proposed CLIA was established, and its validation parameters were assessed as per the guidelines for the validation of immunoassays for bioanalysis. The working dynamic range of the assay was 10-800 pg mL-1 with a limit of detection (LOD) of 10.3 pg mL-1. The assay enables the accurate and precise quantitation of DUR in human plasma at a concentration as low as 30.8 pg mL-1. The CLIA protocol is simple and convenient; an analyst can analyse several hundreds of samples per working day. This high throughput property enables the processing of many samples in clinical settings. The proposed CLIA has a significant benefit in the quantitation of DUR in clinical settings for assessment of its PK, TDM and refining the safety profile.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。