Ionisable substances chromatography: A new approach for the determination of Ketoprofen, Etoricoxib, and Diclofenac sodium in pharmaceuticals using ion - pair HPLC

可电离物质色谱法:使用离子对 HPLC 测定药物中的酮洛芬、依托昔布和双氯芬酸钠的新方法

阅读:5
作者:Georgeos Andraws, Saleh Trefi

Abstract

An ion-pair HPLC method was developed and validated to analyze three of non-steroidal anti-inflammatory drugs (Ketoprofen, Etoricoxib, and Diclofenac sodium) in their pure and pharmaceuticals based on their ionisable characteristics. Cetyltrimethylammonium bromide (Cetrimide) was used as an ion pair reagent since it had not been used before for this purpose. Chromatographic analysis was accomplished using the C18 (250 × 4.6 mm, 5μm) column. Mobile phase consisted of a mixture of 50% Cetrimide 10-310−3<math><mrow><mspace></mspace> <msup><mn>10</mn> <mrow><mo>-</mo> <mn>3</mn></mrow> </msup> </mrow> </math> M and 50% acetonitrile to analyze Ketoprofen and Etoricoxib, whereas for Diclofenac sodium, mobile phase was a mixture of 30% Cetrimide 10-310−3<math><mrow><mspace></mspace> <msup><mn>10</mn> <mrow><mo>-</mo> <mn>3</mn></mrow> </msup> </mrow> </math> M and 70% acetonitrile. pH value was adjusted if necessary to 10 with ammonium hydroxide. The flow rate was 1mL/min and detection wavelengths were at 254 nm, 234 nm, and 254 nm for Ketoprofen, Etoricoxib, and Diclofenac sodium; respectively under ambient temperature. Retention times ( RtRt<math> <mrow><msub><mtext>R</mtext> <mtext>t</mtext></msub> </mrow> </math> ) were 9.41, 7.34, and 6.66 for Ketoprofen, Etoricoxib, and Diclofenac sodium; respectively. The proposed method was evaluated for linearity, accuracy, precision, and specificity according to ICH guidelines. Ketoprofen, Etoricoxib, and Diclofenac sodium were detected in the following linear ranges: (0.031-0.500mg/mL), (0.007-0.110g/mL), and (0.016-0.250mg/mL); respectively with excellent mean recovery values (98.0-102.0%). RSD% was in an acceptable range (less than 2), proving the precision of the developed method. Specificity was proved in the presence of degradation products. Furthermore, a comparison between the results of this study and the reported HPLC methods indicated that this developed method was better in terms of simplicity, analysis time, and no use of buffers in the mobile phase. In conclusion, the developed method can successfully detect Ketoprofen, Etoricoxib, and Diclofenac sodium quantitatively and qualitatively in their dosage forms without any interference with excipients, making this method valuable, reliable, and practical to be applied in quality control laboratories.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。