Effects of Gas Production Recording System and Pig Fecal Inoculum Volume on Kinetics and Variation of In Vitro Fermentation using Corn Distiller's Dried Grains with Solubles and Soybean Hulls

产气记录系统和猪粪接种量对玉米酒糟及可溶物和大豆皮体外发酵动力学及变化的影响

阅读:5
作者:Jae-Cheol Jang, Zhikai Zeng, Gerald C Shurson, Pedro E Urriola

Abstract

An experiment was conducted to investigate the effect of inoculum volume (IV), substrate quantity, and the use of a manual or automated gas production (GP) recording system for in vitro determinations of fermentation of corn distillers dried grains with solubles (cDDGS) and soybean hulls (SBH). A 2 × 2 × 2 factorial arrangement of treatments was used and included the factors of (1) ingredients (cDDGS or SBH), (2) inoculum volume and substrate quantity (IV30 = 0.2 g substrate + 30 mL inoculum or IV75 = 0.5 g substrate + 75 mL inoculum), and (3) GP recording system (MRS = manual recording system or ARS = automated recording system). Feed ingredient samples were pre-treated with pepsin and pancreatin, and the hydrolyzed residues were subsequently incubated with fresh pig feces in a buffered mineral solution. The GP recording was monitored for 72 h, and the kinetics were estimated by fitting data using an exponential model. Compared with SBH, cDDGS yielded less (p < 0.01) maximal gas production (Gf), required more time (p < 0.02) to achieve half gas accumulation (T/2), and had less (p < 0.01) fractional rate of degradation (µ) and in vitro fermentability of dry matter (IVDMF). Using the ARS resulted in less IVDMF (p < 0.01) compared with MRS (79.0% vs. 81.2%, respectively). Interactions were observed between GP recording system and inoculum volume and substrate quantity for Gf (p < 0.04), µ (p < 0.01), and T/2 (p < 0.04) which implies that increasing inoculum volume and substrate quantity resulted in decreased Gf (332 mL/g from IV30 vs. 256 mL/g from IV75), µ (0.05 from IV30 vs. 0.04 from IV75), and T/2 (34 h for IV30 vs. 25 h for IV75) when recorded with ARS but not MRS. However, the recorded cumulative GP at 72 h was not influenced by the inoculum volume nor recording system. The precision of Gf (as measured by the coefficient of variation of Gf) tended to increase for IV30 compared with IV75 (p < 0.10), indicating that using larger inoculum volume and substrate quantity (IV75) reduced within batch variation in GP kinetics. Consequently, both systems showed comparable results in GP kinetics, but considering convenience and achievement of consistency, 75 mL of inoculum volume with 0.5 g substrate is recommended for ARS.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。