Background
Intensity modulated radiotherapy is an efficient radiotherapy technique to increase dose in target volumes and decrease irradiation dose in organs at risk. This last
Conclusions
IMRT with HT allows a better conformity treatment, a more frequently acceptable PTV-V95% than 3D-RT and, concomitantly, a better shielding of the kidneys. The integral doses are comparable between both techniques but consideration of differences in dose distribution between the two techniques, for the organs at risk, has to be taken in account when validating treatment.
Results
The conformity index was statistically better for HT than for 3D-RT. PTV-V95% constraint was reached in 6 cases with HT compared to 2 cases with 3D-RT. For the ipsilateral kidney of the tumor, the V12 Gy constraint was reached for 3 patients with both methods. The values were lower with HT than with 3D-RT in two cases and higher in one case. The threshold was not reached for one patient with either technique, but the value was lower with HT than with 3D-RT. For the contralateral kidney of the tumors, the V12 Gy constraint was reached for all patients with both methods. The values were lower with HT than with 3D-RT in 5 of 7 children, equal in one patient and higher in one patient. The organ-at-risk volumes receiving low doses were significantly lower with 3D-RT but larger for the highest doses, compared to those irradiated with HT. The integral doses were not different. Conclusions: IMRT with HT allows a better conformity treatment, a more frequently acceptable PTV-V95% than 3D-RT and, concomitantly, a better shielding of the kidneys. The integral doses are comparable between both techniques but consideration of differences in dose distribution between the two techniques, for the organs at risk, has to be taken in account when validating treatment.