Modeling a pesticide remediation strategy for preparative liquid chromatography using high-performance liquid chromatography

使用高效液相色谱法模拟制备液相色谱法的农药修复策略

阅读:6
作者:Jamie Cuchiaro, James Baumgartner, Melissa M Reynolds

Background

Cannabis sativa L. also known as industrial hemp, is primarily cultivated as source material for cannabinoids cannabidiol (CBD) and ∆9-tetrahydrocannabinol (∆9-THC). Pesticide contamination during plant growth is a common issue in the cannabis industry which can render plant biomass and products made from contaminated material unusable. Remediation strategies to ensure safety compliance are vital to the industry, and special consideration should be given to

Conclusions

The benchtop method was demonstrated have congruent elution profiles using preparative-scale stationary phase. The resolution of pesticides from cannabinoids in this method indicates that eluent fractionation is a highly attractive industrial solution for pesticide remediation of contaminated cannabis materials and targeted isolation of cannabinoids.

Discussion

7-OH-CBD is a metabolite of CBD and was not observed in the cannabis matrices evaluated. Thus, the present method is suitable for separating 7/11 pesticides and 25/26 cannabinoids tested in the six cannabis matrices tested. 7-OH-CBD, pyrethrins I and II (RTA: 6.8 min, RTB: 10.5 min), permethrin (RTA: 11.9 min, RTB: 12.2 min), and piperonyl butoxide (RTA: 8.3 min, RTB: 11.7 min), will require additional fractionation or purification steps. Conclusions: The benchtop method was demonstrated have congruent elution profiles using preparative-scale stationary phase. The resolution of pesticides from cannabinoids in this method indicates that eluent fractionation is a highly attractive industrial solution for pesticide remediation of contaminated cannabis materials and targeted isolation of cannabinoids.

Methods

The present study evaluated the benchtop-scale suitability of pesticide remediation by liquid chromatographic eluent fractionation, by comparing retention times of 11 pesticides relative to 26 cannabinoids. The ten pesticides evaluated for retention times are clothianidin, imidacloprid, piperonyl butoxide, pyrethrins (I/II mixture), diuron, permethrin, boscalid, carbaryl, spinosyn A, and myclobutanil. Analytes were separated prior to quantification on an Agilent Infinity II 1260 high performance liquid chromatography with diode array detection (HPLC-DAD). The detection wavelengths used were 208, 220, 230, and 240 nm. Primary studies were performed using an Agilent InfinityLab Poroshell 120 EC-C18 3.0 × 50 mm column with 2.7 μm particle diameter, using a binary gradient. Preliminary studies on Phenomenex Luna 10 μm C18 PREP stationary phase were performed using a 150 × 4.6 mm column.

Results

The retention times of standards and cannabis matrices were evaluated. The matrices used were raw cannabis flower, ethanol crude extract, CO2 crude extract, distillate, distillation mother liquors, and distillation bottoms. The pesticides clothianidin, imidacloprid, carbaryl, diuron, spinosyn A, and myclobutanil eluted in the first 3.6 min, and all cannabinoids (except for 7-OH-CBD) eluted in the final 12.6 min of the 19-minute gradient for all matrices evaluated. The elution times of 7-OH-CBD and boscalid were 3.44 and 3.55 min, respectively.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。