Background

This study investigated the miscibility of carbon-based fillers within industrial scale polymers for the preparation of superior quality polymer composites. It focuses on finding the light distribution in gamma irradiated ultra-high molecular weight polyethylene (UHMWPE). (2)

Conclusions

The investigations revealed that there was a significant decrease in absorption and scattering coefficient (μa & μs) values with irradiation, and 30 kGy irradiated samples suffered more compared to 100 kGy irradiated samples. Furthermore, the simulation of light transport for 800 nm showed an increase in penetration depth for UHMWPE after gamma irradiation. The decrease in dimensionless transport albedo  μs(μa+μs) from 0.95 to 0.93 was considered responsible for this increase in photon absorption per unit area with irradiation. The report results are of particular importance when considering the light radiation (from 600 nm to 899 nm) for polyethylene modification and/or stabilization via enhancing the polyethylene chain mobility.

Methods

The Kubleka-Munk model (KMM) was used to extract the optical properties, i.e., absorption coefficients (μa) and scattering coefficients (μs). Samples amounting to 30 kGy and 100 kGy of irradiated (in the open air) UHMWPE from 630 nm to 800 nm were used for this purpose. Moreover, theoretical validation of experimental

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。