日期:
2020 年 — 2026 年
2020
2021
2022
2023
2024
2025
2026
影响因子:

Are current total knee arthroplasty implants tested and approved for personalised alignment?

目前用于全膝关节置换术的植入物是否经过测试和批准,可以进行个性化对位?

Böhle, Sabrina; Bauer, Leandra; Woiczinski, Matthias; Matziolis, Georg

Deep learning of wrist accelerometry from UK Biobank data identifies early movement signatures of knee osteoarthritis up to 5 years before diagnosis

利用英国生物银行数据进行腕部加速度计深度学习,可识别膝骨关节炎早期运动特征,最早可在确诊前5年发现。

Smits Serena, Ricardo; Hirschmann, Michael T; Matziolis, Georg; von Eisenhart-Rothe, Rüdiger; Rueckert, Daniel; Hinterwimmer, Florian; Valle, Christina

Lower synovial leucocyte count and polymorphonuclear percentage reliably differentiate periprosthetic joint infection after unicompartmental knee arthroplasty

滑液白细胞计数和多形核细胞百分比降低可可靠地区分单髁膝关节置换术后假体周围关节感染。

Donner, Stefanie; Matziolis, Georg; Gramlich, Yves; Lazic, Igor; Schrednitzki, Daniel; Pohrt, Anne; Renz, Nora; Meißner, Nils

Properly designed femoral stem impactors help to avoid overstuffing and make a second trial reduction unnecessary

设计合理的股骨柄冲击器有助于避免过度填充,从而避免二次复位尝试。

Brodt, Steffen; Rohe, Sebastian; Knospe, Philipp; Sanz-Ruiz, Pablo; Wassilew, Georgi; Matziolis, Georg

No differences in functional and clinical outcomes after rehabilitation between modified kinematic and mechanical alignment in total knee arthroplasty: A randomized controlled trial

全膝关节置换术后,改良运动学对线与力学对线在康复后的功能和临床结果方面无差异:一项随机对照试验

Bauer, Leandra; Layher, Frank; Kirschberg, Julia; Heinecke, Markus; Woiczinski, Matthias; Matziolis, Georg

Beyond Bioactive Glass Composition: Using Morphology to Improve In Vitro and In Vivo Performance

超越生物活性玻璃的组成:利用形态学改善体外和体内性能

Su, Meixin; Ergin, Mert; Horkavcová, Diana; Horbert, Victoria; Matziolis, Georg; Brauer, Delia S

4D-Spatiotemporal SHG Imaging for the Analysis of Drug-Induced Changes in the Dura Mater

4D时空SHG成像技术在分析药物引起的硬脑膜变化中的应用

Schultz, Constanze; Rodewald, Marko; Weidisch, Andreas; Meyer-Zedler, Tobias; Caffard, Thomas; Schmitt, Michael; Matziolis, Georg; Zippelius, Timo; Popp, Jürgen

A rig for in vitro testing of the lumbar spine and pelvis simulating posterior, anterior and oblique trunk muscles

用于体外测试腰椎和骨盆的装置,可模拟躯干后侧、前侧和斜侧肌肉。

Matziolis, Georg; Bergner, Leah; Hawi, Harun; Bauer, Leandra; Woiczinski, Matthias; Strube, Patrick; Vogt, Sophia

Low-energy shock waves improve the bacterial detection of Staphylococcus aureus biofilms on polyethylene

低能量冲击波可提高聚乙烯表面金黄色葡萄球菌生物膜的细菌检测率。

Böhle, Sabrina; Horbert, Victoria; Rohe, Sebastian; Lindemann, Chris; Röhner, Eric; Matziolis, Georg

Evaluating cell viability assessment techniques: a comparative study of flow cytometry and fluorescence microscopy in response to bioactive glass exposure

评估细胞活力评估技术:流式细胞术和荧光显微镜对生物活性玻璃暴露反应的比较研究

Samuel, Bolaji J; Jin, Zhaorui; Brauer, Delia S; Matziolis, Georg; Horbert, Victoria