日期:
2020 年 — 2026 年
2020
2021
2022
2023
2024
2025
2026
影响因子:

Fit of Three-Unit Posterior Fixed Dental Prostheses Made from Tetragonal Zirconia Polycrystal by 3D Printing and Milling

采用3D打印和铣削技术制作的四方氧化锆多晶体三单元后牙固定义齿的适配性

Kostunov, Jana; Crocoll, Jannis; Hetzler, Sebastian; Rammelsberg, Peter; Zeiß, Jonas; Zenthöfer, Andreas; Rues, Stefan

Biaxial Flexural Strength and Vickers Hardness of 3D-Printed and Milled 5Y Partially Stabilized Zirconia

3D打印和铣削5Y部分稳定氧化锆的双轴弯曲强度和维氏硬度

Hetzler, Sebastian; Hinzen, Carina; Rues, Stefan; Schmitt, Clemens; Rammelsberg, Peter; Zenthöfer, Andreas

Fracture Resistance of 3-Unit Zirconia Fixed Dental Prostheses Differing in Wall Thickness Fabricated by Either 3D-Printing or Milling

采用3D打印或铣削工艺制作的不同壁厚的三单元氧化锆固定式牙科修复体的抗断裂性能

Rues, Stefan; Crocoll, Jannis; Hetzler, Sebastian; Rossipal, Johannes; Rammelsberg, Peter; Zenthöfer, Andreas

Biological Response of Osteoblasts to Zirconia Manufactured via FFF, DLP, and Milling

成骨细胞对通过 FFF、DLP 和铣削工艺制造的氧化锆的生物学反应

Roser, Christoph J; Erber, Ralf; Zenthöfer, Andreas; Rues, Stefan; Lux, Christopher J; Nötzel, Dorit; Eickhoff, Ralf; Hanemann, Thomas

Digital Occlusal Contact Area Indicates Masticatory Performance for Normal Occlusion, but Not for Malocclusion

数字咬合接触面积可以反映正常咬合的咀嚼功能,但不能反映错颌畸形的咀嚼功能。

Vortkamp, Paulina; Rues, Stefan; Räther, Sven; Eberhard, Lydia; Rößler, Alexander; Bouffleur, Frederic; Kühle, Reinald; Schwindling, Franz Sebastian; Rammelsberg, Peter; Roser, Christoph J; Herpel, Christopher

Dimensional Accuracy of Regular- and Fast-Setting Vinyl Polysiloxane Impressions Using Customized Metal and Plastic Trays-An In Vitro Study

使用定制金属和塑料托盘对常规和快速固化乙烯基聚硅氧烷印模进行尺寸精度测定——一项体外研究

Waldecker, Moritz; Jetter, Karla; Rues, Stefan; Rammelsberg, Peter; Zenthöfer, Andreas

Fracture Toughness, Work of Fracture and Hardness of 3D-Printed Denture Base Resins

3D打印义齿基托树脂的断裂韧性、断裂功和硬度

Hetzler, Sebastian; Rehm, Sebastian; Räther, Sven; Rues, Stefan; Zenthöfer, Andreas; Rammelsberg, Peter; Schwindling, Franz Sebastian

Fitting Accuracy and Constraint Force Measurement of Complete-Arch Implant-Supported Fixed Dental Prostheses Made from Cobalt-Chromium and Zirconia Frameworks Based on the All-on-Four Treatment Concept

基于All-on-Four治疗理念的钴铬合金和氧化锆支架全口种植支持式固定义齿的就位精度和约束力测量

Horsch, Laura; Kirsch, Cedric; Zenthöfer, Andreas; Rammelsberg, Peter; Richter, Kevin; Rues, Stefan

In-vitro validation of a new method to assess the clinical accuracy of complete arch impressions

体外验证一种评估全牙弓印模临床准确性的新方法

Waldecker, Moritz; Katherina, Schessler; Wolfgang, Bömicke; Peter, Rammelsberg; Stefan, Rues

Comparison of six different CAD/CAM retainers vs. the stainless steel twistflex retainer: an in vitro investigation of survival rate and stability

六种不同的CAD/CAM固位体与不锈钢Twistflex固位体的比较:体外存活率和稳定性研究

Roser, Christoph J; Bauer, Carolien; Hodecker, Lutz; Zenthöfer, Andreas; Lux, Christopher J; Rues, Stefan