日期:
2020 年 — 2026 年
2020
2021
2022
2023
2024
2025
2026
影响因子:

Monte Carlo-based dosimetric comparison of indigenous and commercial (106)Ru/(106)Rh eye plaques using a mathematical eye phantom

利用数学眼模体,通过蒙特卡罗方法对国产和商用(106)Ru/(106)Rh眼贴片进行剂量学比较

Shrivastava, Vandana; Chattaraj, Arghya; Selvam, T Palani; Pathan, M S; Kumar, Rajesh; Sapra, B K

Monte Carlo calculation of correction factors for determining the operational quantity [Formula: see text] in solid phantoms for ISO narrow series photon sources

利用蒙特卡罗方法计算固体模型中ISO窄系列光子源的操作量[公式:见正文]的校正因子

Shrivastava, Vandana; Selvam, T Palani; Pradhan, S M

Monte Carlo-based Investigation of Absorbed-dose Energy Dependence of Thermoluminescent Dosimeters in Therapeutic Proton and Carbon Ion Beams

基于蒙特卡罗方法的治疗性质子束和碳离子束中热释光剂量计吸收剂量能量依赖性研究

Chattaraj, Arghya; Mishra, Subhalaxmi; Selvam, T Palani

The Analytical Possibilities of FT-IR Spectroscopy Powered by Vibrating Molecules

振动分子驱动的傅里叶变换红外光谱分析的可能性

Koczoń, Piotr; Hołaj-Krzak, Jakub T; Palani, Bharani K; Bolewski, Tymoteusz; Dąbrowski, Jarosław; Bartyzel, Bartłomiej J; Gruczyńska-Sękowska, Eliza

Monte Carlo Study on Dose Distributions Around (192)Ir, (169)Yb, and (125)I Brachytherapy Sources Using EGSnrc-based egs_brachy User-code

基于EGSnrc的egs_brachy用户代码对(192)Ir、(169)Yb和(125)I近距离放射治疗源周围的剂量分布进行蒙特卡罗研究

Mishra, Subhalaxmi; Mishra, Bibekananda; Selvam, T Palani; Deshpande, Sudesh; Pathan, Munir Shabbir; Kumar, Rajesh

Monte Carlo Calculation of Beam Quality and Phantom Scatter Corrections for Lithium Formate Electron Paramagnetic Resonance Dosimeter for High-energy Brachytherapy Dosimetry

利用蒙特卡罗方法计算甲酸锂电子顺磁共振剂量计在高能近距离放射治疗剂量测定中的束流质量和体模散射校正

Mishra, Subhalaxmi; Selvam, T Palani

Dosimetry of indigenously developed (192)Ir high-dose rate brachytherapy source: An EGSnrc Monte Carlo study

国产(192)Ir高剂量率近距离放射治疗源的剂量测定:EGSnrc蒙特卡罗研究

Sahoo, Sridhar; Selvam, T Palani; Sharma, S D; Das, Trupti; Dey, A C; Patil, B N; Sastri, K V S

Monte Carlo-based Spencer-Attix and Bragg-Gray tissue-to-air stopping power ratios for ISO beta sources

基于蒙特卡罗方法的Spencer-Attix和Bragg-Gray组织-空气阻止本领比(适用于ISO β源)

Selvam, T Palani; Vandana, S; Bakshi, A K; Babu, D A R

Monte Carlo calculation of beam quality correction for solid-state detectors and phantom scatter correction at 137Cs energy

利用蒙特卡罗方法计算固态探测器的光束质量校正和137Cs能量下的体模散射校正

Selvam, T Palani; Mishra, Subhalaxmi; Vishwakarma, R S

Monte Carlo-based beam quality and phantom scatter corrections for solid-state detectors in 60Co and 192Ir brachytherapy dosimetry

基于蒙特卡罗方法的固态探测器在 60Co 和 192Ir 近距离放射治疗剂量测定中的束流质量和体模散射校正

Subhalaxmi, Mishra; Selvam, T Palani