Dynamic driving pressure predicts ventilator-induced lung injury in mice with and without endotoxin-induced acute lung injury.

动态驱动压力可预测有或无内毒素诱导的急性肺损伤的小鼠的呼吸机诱导肺损伤

阅读:29
作者:Wallbank Alison, Sosa Alexander, Colson Andrew, Farooqi Huda, Kaye Elizabeth, Warner Katharine, Albers David J, Sottile Peter D, Smith Bradford J
Mechanical ventilation (MV) is a necessary lifesaving intervention for patients with acute respiratory distress syndrome (ARDS) but it can cause ventilator-induced lung injury (VILI), which contributes to the high ARDS mortality rate (∼40%). Bedside determination of optimally lung-protective ventilation settings is challenging because the evolution of VILI is not immediately reflected in clinically available, patient-level, data. The goal of this work was therefore to test ventilation waveform-derived parameters that represent the degree of ongoing VILI and can serve as targets for ventilator adjustments. VILI was generated at three different positive end-expiratory pressures in a murine inflammation-mediated (lipopolysaccharide, LPS) acute lung injury model and in initially healthy controls. LPS injury increased the expression of proinflammatory cytokines and caused widespread atelectasis, predisposing the lungs to VILI as measured in structure, mechanical function, and inflammation. Changes in lung function were used as response variables in an elastic net regression model that predicted VILI severity from tidal volume, dynamic driving pressure (PD(Dyn)), mechanical power calculated by integration during inspiration or the entire respiratory cycle, and power calculated according to Gattinoni' s equation. Of these, PD(Dyn) best predicted functional outcomes of injury using either data from the entire dataset or from 5-min time windows. The windowed data show higher predictive accuracy after an ∼1-h "run in" period and worse accuracy immediately following recruitment maneuvers. This analysis shows that low driving pressure is a computational biomarker associated with better experimental VILI outcomes and supports the use of driving pressure to guide ventilator adjustments to prevent VILI.NEW & NOTEWORTHY Elastic net regression analysis of ventilation waveforms recorded during mechanical ventilation of initially healthy and lung-injured mice shows that low driving pressure is a computational biomarker associated with better ventilator-induced lung injury (VILI) outcomes and supports the use of driving pressure to guide ventilator adjustments to prevent VILI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。