Serum matrix metalloproteinase-7 for discriminating biliary atresia: a diagnostic accuracy and validation study

血清基质金属蛋白酶-7 对胆道闭锁的鉴别:诊断准确性和验证研究

阅读:6
作者:Jingying Jiang #, Rui Dong #, Min Du #, Gong Chen, Jingyun Yang, Xinbao Xie, Yifan Yang, Weili Yan, Shan Zheng

Background

Prompt and precise differential diagnosis of biliary atresia (BA) among cholestatic patients is of great importance. Matrix metalloproteinase-7 (MMP-7) holds great promise as a diagnostic marker for BA. This study aimed to investigate the accuracy of age-specific serum MMP-7 for discriminating BA from other cholestatic pediatric patients.

Conclusions

The serum MMP-7 is accurate and reliable in differentiating BA from non-BA cholestasis, showing its potential application in the diagnostic algorithm for BA and significant role in the future research regarding pathogenesis of BA.

Methods

This was a single center diagnostic accuracy and validation study including both retrospective and prospective cohorts. Serum MMP-7 concentrations were measured using an ELISA kit, the trajectory of which with age was investigated in a healthy infants cohort aged 0 to 365 days without hepatobiliary diseases (n = 284). Clinical BA diagnosis was based on intraoperative cholangiography and subsequent histological examinations. The diagnostic accuracy of age-specific cutoffs of serum MMP-7 were assessed in a retrospective cohort of cholestatic patients (n = 318, with 172 BA) and validated in a prospective cohort (n = 687, including 395 BA).

Results

The MMP-7 concentration declines non-linearly with age, showing higher levels in healthy neonates as well as higher cutoff value in neonatal cholestasis. The area under the ROC curve (AUROC) was 0.967 (95% confidence interval [CI]: 0.946-0.988) for the retrospective cohort, and the cutoff of 18 ng/mL yielded 93.0% (95%CI: 88.1-96.3%), 93.8% (95%CI: 88.6-97.1%), 94.7% (95%CI: 90.1-97.5%), and 91.9% (95%CI: 86.4-95.8%) for sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), respectively. The performance of MMP-7 was successfully validated in the larger prospective cohort, resulting in a diagnostic sensitivity of 95.9% (379/395; 95% CI: 93.5-97.7%), a specificity of 87.3% (255/292; 95% CI: 83.0-90.9%), a PPV of 91.1% (379/416; 95% CI: 87.9-93.7%), and a NPV of 94.1% (255/271; 95% CI: 90.6-96.6%), respectively. Besides, higher cutoff value of 28.1 ng/mL achieved the best sensitivity, specificity, PPV, and NPV for infants aged 0-30 days, which was 86.4% (95% CI: 75.0-94.0%), 95.5% (95% CI: 77.2-99.9%), 98.1% (95% CI: 89.7-100%), and 72.4% (95% CI: 52.8-87.3%), respectively. Conclusions: The serum MMP-7 is accurate and reliable in differentiating BA from non-BA cholestasis, showing its potential application in the diagnostic algorithm for BA and significant role in the future research regarding pathogenesis of BA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。