Evaluation of OAR dose sparing and plan robustness of beam-specific PTV in lung cancer IMRT treatment.

阅读:3
作者:Chang Yu, Xiao Feng, Quan Hong, Yang Zhiyong
PURPOSE: Margins are employed in radiotherapy treatment planning to mitigate the dosimetric effects of geometric uncertainties for the clinical target volume (CTV). Here, we proposed a margin concept that takes into consideration the beam direction, thereby generating a beam-specific planning target volume (BSPTV) on a beam entrance view. The total merged BSPTV was considered a target for optimization. We investigated the impact of this novel approach for lung intensity-modulated radiotherapy (IMRT) treatment, and compared the treatment plans generated using BSPTV with general PTV. METHODS AND MATERIALS: We generated the BSPTV by expanding the CTV perpendicularly to the incident beam direction using the 2D version of van Herk's margin concept. The BSPTV and general PTV margin were analyzed using digital phantom simulation. Fifteen lung cancer patients were used in the planning study. First, all patient targets were performed with the CTV projection area analysis to select the suitable beam angles. Then, BSPTV was generated according to the selected beam angles. IMRT plans were optimized with the general PTV and BSPTV as the target volumes, respectively. The dosimetry metrics were calculated and evaluated between these two plans. The plan robustness of both plans for setup uncertainties was evaluated using worst-case analysis. RESULTS: Both general PTV and BSPTV plans satisfied the CTV coverage. In addition, the BSPTV plans improved the sparing of high doses to target-surrounding lung tissues compared to the general PTV plans. Both D(mean) of Ring PTV and Ring BSPTV were significantly lower in BSPTV plans (38.89 Gy and 39.43 Gy) compared to the general PTV plans (40.27 Gy and 40.68 Gy). The V20, V5, and mean lung dose of the affected lung were significant lower in BSPTV plans (16.20%, 28.75% and 8.93 Gy) compared to general PTV plans (16.69%, 29.22% and 9.18 Gy). In uncertainty scenarios, about 80% of target coverage was achieved for both general PTV and BSPTV plans. CONCLUSIONS: The results suggested that plan robustness can be guaranteed in both the BSPTV and general PTV plans. However, the BSPTV plan spared normal tissues, such as the lungs, significantly better compared to the general PTV plans.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。