BACKGROUND: Based on a previous study on the feasibility of TomoEQA, an exit detector-based patient-specific pre-treatment quality assurance (QA) method for helical tomotherapy, an in-depth clinical evaluation was conducted. METHODS: Data of one hundred patients were analyzed to evaluate the clinical usefulness of TomoEQA for patient-specific pre-treatment QA in comparison with the conventional phantom-based method. Additional investigations were also performed under unusual measurement conditions to validate the off-axis region. In addition to the clinical evaluation of TomoEQA, a statistical analysis was conducted to determine the plan parameters that affect the pass/failure results of pre-treatment QA. RESULTS: The average and standard deviations of the gamma passing rate and point dose error for TomoEQA were comparable to those of the conventional QA method. For TomoEQA, the average values of the gamma passing rate and point dose error were 96.32% (standard deviation (1 sigma)â=â3.94; 95% confidence interval (CI), 95.55 to 97.09) and -â1.12% (standard deviation (1 sigma)â=â1.04; CI, -â1.32 to -â0.92), respectively. For the conventional QA method, the average values of the gamma passing rate and point dose error were 95.95% (standard deviation (1 sigma)â=â4.35; 95% confidence interval (CI), 95.10 to 96.80) and -â1.20% (standard deviation (1 sigma)â=â1.61; CI, -â1.52 to -â0.88), respectively. Further experiments on the off-axis region demonstrated that TomoEQA can provide accurate results for 3D dose analysis, which is inherently difficult in the conventional QA method. Through a statistical analysis based on the results of TomoEQA, it was validated that the total fraction (Total Fx), monitor units, beam-on-time, leaf-of-time below 100Â ms, and planning target volume diameter were statistically significant for the pass/failure of the pre-treatment QA results. CONCLUSIONS: TomoEQA is a clinically beneficial alternative to the conventional phantom-based QA method.
Comprehensive clinical evaluation of TomoEQA for patient-specific pre-treatment quality assurance in helical tomotherapy.
阅读:4
作者:Kim Changhwan, Han Min Cheol, Lee Young Kyu, Shin Han-Back, Kim Hojin, Kim Jin Sung
| 期刊: | Radiation Oncology | 影响因子: | 3.200 |
| 时间: | 2022 | 起止号: | 2022 Nov 7; 17(1):177 |
| doi: | 10.1186/s13014-022-02151-x | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
