An increasing number of measurement electrodes have been designed to satisfy the demand for high-resolution detection using galvanic logging technology in complex formations. The forward modeling response analysis of logging tools has important guiding significance in the design of galvanic logging tools. Based on a three-dimensional finite element numerical simulation method, we established a forward model of galvanic multi-electrodes in a complex formation. We also designed a symmetrical resistance network model of the formation with equivalent resistance between two electrodes. A symmetrical resistance network was derived using the balanced bridge method. The asymmetrical admittance matrix was extended to a symmetrical extended admittance matrix to realize a convenient calculation of the equivalent symmetrical resistance network in complex formations. Verification of the microcolumn-focused logging tool, with nine electrodes in a simulated standard well, and an evaluation of the degree of invasion in an actual oil well indicate that this calibration method can improve the measurement accuracy of galvanic logging instruments.
A standard calibration method based on a symmetric resistance network matrix for galvanic logging instruments.
阅读:3
作者:Ji Yongli, Li Zhiqiang, Xia Jigen, Song Jiajia
| 期刊: | PLoS One | 影响因子: | 2.600 |
| 时间: | 2024 | 起止号: | 2024 Apr 17; 19(4):e0302032 |
| doi: | 10.1371/journal.pone.0302032 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。