Chloride presence affects different environments (soil, water, concrete) decreasing their qualities. In order to assess chloride concentration this paper proposes a novel sensor for detecting and measuring it. This sensor is based on electric changes of commercial monocalcium aluminate (CA) when it interacts with chloride aqueous solutions. CA is used as a dielectric material between two coplanar capacitors. The geometry proposed for this sensor allows to assess the chloride content profile, or to make four times the same measurement. Besides, the experimental design gives us the possibility of study not just the chloride effect, but also the time and some geometric effects due to the sensor design. As a result, this sensor shows a limit of detection, sensitivity, and response time: 0.01 wt % Cl(-) and 0.06 wt % Cl(-), and 2 min, respectively, comparable with other non invasive techniques as optical fibre sensors.
Chlordetect: Commercial Calcium Aluminate Based Conductimetric Sensor for Chloride Presence Detection.
阅读:3
作者:Torres-Luque Magda, Osma Johann F, Sánchez-Silva Mauricio, Bastidas-Arteaga Emilio, Schoefs Franck
| 期刊: | Sensors | 影响因子: | 3.500 |
| 时间: | 2017 | 起止号: | 2017 Sep 13; 17(9):2099 |
| doi: | 10.3390/s17092099 | ||
特别声明
1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。
2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。
3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。
4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。