In this paper, we present robust methods for automatically segmenting phases in a specified surgical workflow by using latent Dirichlet allocation (LDA) and hidden Markov model (HMM) approaches. More specifically, our goal is to output an appropriate phase label for each given time point of a surgical workflow in an operating room. The fundamental idea behind our work lies in constructing an HMM based on observed values obtained via an LDA topic model covering optical flow motion features of general working contexts, including medical staff, equipment, and materials. We have an awareness of such working contexts by using multiple synchronized cameras to capture the surgical workflow. Further, we validate the robustness of our methods by conducting experiments involving up to 12 phases of surgical workflows with the average length of each surgical workflow being 12.8 minutes. The maximum average accuracy achieved after applying leave-one-out cross-validation was 84.4%, which we found to be a very promising result.
Phase Segmentation Methods for an Automatic Surgical Workflow Analysis.
阅读:5
作者:Tran Dinh Tuan, Sakurai Ryuhei, Yamazoe Hirotake, Lee Joo-Ho
| 期刊: | International Journal of Biomedical Imaging | 影响因子: | 1.300 |
| 时间: | 2017 | 起止号: | 2017;2017:1985796 |
| doi: | 10.1155/2017/1985796 | ||