Accurate central surface radius of curvature (RoC) measurements of isolated human lenses are essential for understanding the zonular forces required to modify human lens shape to focus at near; i.e., accommodate. The human lens can be described as an encapsulated oblate spheroid, with its minor axis aligned with its optical axis. The lens is suspended by zonular fibers that originate from the epithelium of the ciliary body and insert into the equatorial region of the lens capsule. According to Helmholtz's theory of accommodation when the eye views a distant object (the unaccommodated state), the ciliary muscle is fully relaxed and the zonules are under maximal tension. This tension flattens both the central and peripheral lens surfaces resulting in minimal central optical power (COP). During near focus (accommodation), contraction of the ciliary muscle reduces zonular tension, allowing the elastic capsule to restore the lens to a more rounded shape. This increases the curvature of the lens surfaces, central thickness, and COP. Consequently, isolated lenses without zonular tension from young donors (20-30 years old) would be expected to exhibit maximum COP. However, the companion independent profilometric equation fitting study found that, within central optical zonesââ¤â3âmm, 10 fresh isolated lenses from donors in this age range actually had minimal COP. The present study utilizes a white light scanning interferometer (WLSI) with a 10x objective that was validated by measuring RoCs of glass and porcine lenses. Fourteen transparent human lenses were obtained from both eyes of seven donors aged 20-30 years of whom 2 were female and 5 were male. One lens of each donor was placed in preservative media and the contralateral lens in culture media within 11:26â±â5:15 (range: 4:47-21:54) of the donor's death. Two of the lenses stored in the culture media had torn capsules and were excluded from the study. Central thickness and WLSI surface vertex RoCs of 12 lenses were measured within 16:27â±â5:22 (range: 10:11-25:33) of the donor's death. Mean central thickness, anterior and posterior vertex RoCs and COP were 3.54â±â0.07âmm, 10.2â±â0.9âmm, 6.8â±â1.0âmm, and 20.7â±â2.1 diopters, respectively. These results confirm the companion study that isolated human lenses have low COP consistent with the unaccommodated state of lenses in vivo. Therefore, relaxation of all the zonules does not increase COP and cannot be the basis for the mechanism of accommodation. These results have implications for the development and treatment of myopia, presbyopia, glaucoma, cortical cataracts and design of accommodative intraocular lenses.
Isolated human lens interferometric surface radius of curvatures: Implications for the mechanism of accommodation.
人眼晶状体干涉表面曲率半径的孤立测量:对调节机制的启示
阅读:3
作者:Schachar Ronald A, Schachar Ira H, Fabio John, Balicki Dani, Sufi Nabeel, Pierscionek Barbara K, Hunter Boyd
| 期刊: | PLoS One | 影响因子: | 2.600 |
| 时间: | 2025 | 起止号: | 2025 Jun 24; 20(6):e0327028 |
| doi: | 10.1371/journal.pone.0327028 | 种属: | Human |
特别声明
1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。
2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。
3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。
4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。
