Harmonic distortion is one of the dominant factors limiting the overall signal-to-noise and distortion ratio of seismic-grade sigma-delta MEMS accelerometers. This study investigates harmonic distortion based on the multiple degree-of-freedom model (MDM) established in our previous study. The main advantage of using an MDM is that the effect of finger flexibility on harmonic distortion is considered. Initially, the nonlinear relationship between the input acceleration and output signal is derived using the MDM. Then, harmonic distortion is simulated and described in terms of the nonlinear input-output relationship. It is found that finger flexibility and parasitic capacitance mismatch both decrease harmonic distortion. Finally, the experimental testing of harmonic distortion is implemented. By reducing the finger length to realize a higher stiffness and compensating for the parasitic capacitance mismatch, the total harmonic distortion decreases from -66.8 dB to -86.9 dB.
A Study on the Harmonic Distortion of Seismic-Grade Sigma-Delta MEMS Accelerometers Using a Multiple Degree-of-Freedom Model.
阅读:5
作者:Wang Xuefeng, Zhang Penghao, Ding Shijin
| 期刊: | Sensors | 影响因子: | 3.500 |
| 时间: | 2023 | 起止号: | 2023 Oct 2; 23(19):8222 |
| doi: | 10.3390/s23198222 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。