Validation of dual-energy CT-based composition analysis using fresh animal tissues and composition-optimized tissue equivalent samples.

阅读:14
作者:Niepel Katharina, Tattenberg Sebastian, Marants Raanan, Hu Guyue, Bortfeld Thomas, Verburg Joost, Sudhyadhom Atchar, Landry Guillaume, Parodi Katia
Objective.Proton therapy allows for highly conformal dose deposition, but is sensitive to range uncertainties. Several approaches currently under development measure composition-dependent secondary radiation to monitor the delivered proton rangein-vivo. To fully utilize these methods, an estimate of the elemental composition of the patient's tissue is often needed.Approach.A published dual-energy computed tomography (DECT)-based composition-extraction algorithm was validated against reference compositions obtained with two independent methods. For this purpose, a set of phantoms containing either fresh porcine tissue or tissue-mimicking samples with known, realistic compositions were imaged with a CT scanner at two different energies. Then, the prompt gamma-ray (PG) signal during proton irradiation was measured with a PG detector prototype. The PG workflow used pre-calculated Monte Carlo simulations to obtain an optimized estimate of the sample's carbon and oxygen contents. The compositions were also assessed with chemical combustion analysis (CCA), and the stopping-power ratio (SPR) was measured with a multi-layer ionization chamber. The DECT images were used to calculate SPR-, density- and elemental composition maps, and to assign voxel-wise compositions from a selection of human tissues. For a more comprehensive set of reference compositions, the original selection was extended by 135 additional tissues, corresponding to spongiosa, high-density bones and low-density tissues.Results.The root-mean-square error for the soft tissue carbon and oxygen content was 8.5 wt% and 9.5 wt% relative to the CCA result and 2.1 wt% and 10.3 wt% relative to the PG result. The phosphorous and calcium content were predicted within 0.4 wt% and 1.1 wt% of the CCA results, respectively. The largest discrepancies were encountered in samples whose composition deviated the most from tabulated compositions or that were more inhomogeneous.Significance.Overall, DECT-based composition estimations of relevant elements were in equal or better agreement with the ground truth than the established SECT-approach and could contribute toin-vivodose verification measurements.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。