Objective.Proton therapy allows for highly conformal dose deposition, but is sensitive to range uncertainties. Several approaches currently under development measure composition-dependent secondary radiation to monitor the delivered proton rangein-vivo. To fully utilize these methods, an estimate of the elemental composition of the patient's tissue is often needed.Approach.A published dual-energy computed tomography (DECT)-based composition-extraction algorithm was validated against reference compositions obtained with two independent methods. For this purpose, a set of phantoms containing either fresh porcine tissue or tissue-mimicking samples with known, realistic compositions were imaged with a CT scanner at two different energies. Then, the prompt gamma-ray (PG) signal during proton irradiation was measured with a PG detector prototype. The PG workflow used pre-calculated Monte Carlo simulations to obtain an optimized estimate of the sample's carbon and oxygen contents. The compositions were also assessed with chemical combustion analysis (CCA), and the stopping-power ratio (SPR) was measured with a multi-layer ionization chamber. The DECT images were used to calculate SPR-, density- and elemental composition maps, and to assign voxel-wise compositions from a selection of human tissues. For a more comprehensive set of reference compositions, the original selection was extended by 135 additional tissues, corresponding to spongiosa, high-density bones and low-density tissues.Results.The root-mean-square error for the soft tissue carbon and oxygen content was 8.5 wt% and 9.5 wt% relative to the CCA result and 2.1 wt% and 10.3 wt% relative to the PG result. The phosphorous and calcium content were predicted within 0.4 wt% and 1.1 wt% of the CCA results, respectively. The largest discrepancies were encountered in samples whose composition deviated the most from tabulated compositions or that were more inhomogeneous.Significance.Overall, DECT-based composition estimations of relevant elements were in equal or better agreement with the ground truth than the established SECT-approach and could contribute toin-vivodose verification measurements.
Validation of dual-energy CT-based composition analysis using fresh animal tissues and composition-optimized tissue equivalent samples.
阅读:5
作者:Niepel Katharina, Tattenberg Sebastian, Marants Raanan, Hu Guyue, Bortfeld Thomas, Verburg Joost, Sudhyadhom Atchar, Landry Guillaume, Parodi Katia
| 期刊: | Physics in Medicine and Biology | 影响因子: | 3.400 |
| 时间: | 2024 | 起止号: | 2024 Aug 12; 69(16):165033 |
| doi: | 10.1088/1361-6560/ad68bc | ||
特别声明
1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。
2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。
3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。
4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。
