PURPOSE: This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT-based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. METHODS: We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs at 0°, 36°, 72°, 288°, and 324° couch angles, with 2 arcs per couch angle using 45° and 135° collimator angles. Two verification plans using Eclipse v15.6 (AcurosXB) were created with 20 Gy at the maximum dose for: (1) a cylindrical gel, with an additional calibration region; (2) a 3D printed anthropomorphic skull phantom with a gel insert. The 50% isodose (10 Gy) width through the central axis of the axial and sagittal planes (SPs) were measured for the gel experiment. The distance between the centers-of-masses of the 10 Gy isodose region of the plan and the gel (skull phantom) were calculated for an end-to-end spatial accuracy test. RESULTS: The maximum point dose measured with gel was within 1% of the plan, though the gel measured 50% isodose widths of 5.56  ± 0.02 mm, 5.65 ± 0.04 mm, 4.23 ± 0.01 mm for axial (anterior-posterior), axial (left-right), sagittal (superior-inferior) respectively, which were slightly narrower than Eclipse (1.29 mm maximum difference in the SP due to CBCT slice thickness). The center-of-mass distance was 0.66 mm for the gel experiment, and 0.94 mm for complete end-to-end testing with the anthropomorphic phantom, including CBCT setup (kV-MV isocenter uncertainty). CONCLUSION: The 50% isodose width of the gel measurement was 5.15 mm (mean), which was tighter than our Eclipse v15.6 beam model. The end-to-end spatial accuracy test, only achievable with gel dosimetry using CBCT readout, resulted in sub-millimeter accuracy. This study demonstrates the value of gel dosimetry in verifying the dosimetric and spatial accuracy of this high precision, stereotactic technique.
Evaluation of dosimetric and spatial accuracy of a virtual cone technique for radiosurgery using linac-integrated CBCT-based polymer gel dosimetry.
阅读:16
作者:Kunkyab Tenzin, Lamey Michael, Jirasek Andrew, Kudla Michael, Becker Nathan, Mou Benjamin, Hyde Derek
| 期刊: | Journal of Applied Clinical Medical Physics | 影响因子: | 2.200 |
| 时间: | 2025 | 起止号: | 2025 Jun;26(6):e70081 |
| doi: | 10.1002/acm2.70081 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。