BACKGROUND: In the clinical applications of optical coherence tomography angiography (OCTA), the repeated scanning and averaging method can provide better contrast with reduced speckle noises in the final results, which are useful for visualizing and quantifying vascular components with high accuracy, reproducibility, and reliability. However, the inevitable patient motion presents a challenge to this method. The objective of this study is to meet this challenge by introducing a 3D registration method to register optical coherence tomography (OCT)/OCTA scans for precise volume averaging of multiple scans to improve the signal-to-noise ratio (SNR) and increase quantification accuracy. METHODS: The proposed method utilized both rigid affine transformation and non-rigid B-spline transformation in which their parameters were optimized and calculated by the average stochastic gradient descent on OCT structural images. In addition, we also introduced a multi-level resolution approach to further improve the robustness and computational speed of our proposed method. The imaging performance was tested on in vivo imaging of human skin and eye and assessed by SNR, peak signal-to-noise ratio (PSNR) and normalized correlation coefficient (NCC). RESULTS: Five subjects were enrolled in this study for obtaining in vivo images of skin and retina. The proposed registration and averaging method provided substantial improvements of the imaging performance in terms of vessel connectivity and signal to noise ratio. The increase of repeated volume numbers in the averaging improves all the metrics assessed, i.e., SNR, PSNR and NCC. An improvement of the SNR from 10 to 40 dB after 10 repeated volumetric averaging was achieved. CONCLUSIONS: The proposed 3D registration and averaging method is effective in reducing speckle noises and suppressing motion artifacts, thereby improving SNR, PSNR and NCC metrics for final averaged images. It is expected that the proposed algorithm would be practically useful in better visualization and more reliable quantification of in vivo OCT and OCTA data, which would be beneficial to OCT clinical applications.
Robust three-dimensional registration on optical coherence tomography angiography for speckle reduction and visualization.
阅读:15
作者:Cheng Yuxuan, Chu Zhongdi, Wang Ruikang K
| 期刊: | Quantitative Imaging in Medicine and Surgery | 影响因子: | 2.300 |
| 时间: | 2021 | 起止号: | 2021 Mar;11(3):879-894 |
| doi: | 10.21037/qims-20-751 | ||
特别声明
1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。
2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。
3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。
4、投稿及合作请联系:info@biocloudy.com。
