Development of a high-throughput fluorescent no-wash sodium influx assay

高通量荧光免洗钠流入检测方法的开发

阅读:5
作者:Bryan Tay, Teneale A Stewart, Felicity M Davis, Jennifer R Deuis, Irina Vetter

Abstract

Voltage-gated sodium channels (NaVs) are key therapeutic targets for pain, epilepsy and cardiac arrhythmias. Here we describe the development of a no-wash fluorescent sodium influx assay suitable for high-throughput screening and characterization of novel drug leads. Addition of red-violet food dyes (peak absorbance range 495-575 nm) to assays in HEK293 cells heterologously expressing hNaV1.1-1.8 effectively quenched background fluorescence of the sodium indicator dye Asante NaTRIUM Green-2 (ANG-2; peak emission 540 nm), negating the need for a wash step. Ponceau 4R (1 mM) was identified as a suitable quencher, which had no direct effect on NaV channels as assessed by patch-clamp experiments, and did not alter the pharmacology of the NaV1.1-1.7 activator veratridine (EC50 10-29 μM) or the NaV1.1-1.8 inhibitor tetracaine (IC50's 6-66 μM). In addition, we also identified that the food dyes Ponceau 4R, Brilliant Black BN, Allura Red and Amaranth are effective at quenching the background fluorescence of the calcium indicator dyes fluo-4, fura-2 and fura-5F, identifying them as potential inexpensive alternatives to no-wash calcium ion indicator kits. In summary, we have developed a no-wash fluorescent sodium influx assay suitable for high-throughput screening based on the sodium indicator dye ANG-2 and the quencher Ponceau 4R.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。