Adsorption and carbonylation of plasma proteins by dialyser membrane material: in vitro and in vivo proteomics investigations

透析膜材料对血浆蛋白的吸附和羰基化:体外和体内蛋白质组学研究

阅读:8
作者:Barbara Pavone, Vittorio Sirolli, Sonia Bucci, Fulvio Libardi, Paolo Felaco, Luigi Amoroso, Paolo Sacchetta, Andrea Urbani, Mario Bonomini

Background

Protein carbonylation is an irreversible and not reparable reaction which is caused by the introduction into proteins of carbonyl derivatives such as ketones and aldehydes, generated from direct oxidation processes or from secondary protein reaction with reactive carbonyl compounds. Several studies have demonstrated significantly increased levels of reactive carbonyl compounds, a general increase in plasma protein carbonyls and carbonyl formation on major plasma proteins in blood from uremic patients, particularly those undergoing chronic haemodialysis. Materials and

Conclusions

The present study suggests that biomaterials used for fabrication of haemodialysis membrane may affect the carbonyl balance in chronic uremic patients.

Methods

In the present preliminary study, we first assessed by an in vitro filtration apparatus the possible effects of different materials used for haemodialysis membranes on protein retention and carbonylation. We employed hollow fiber minidialyzers of identical structural characteristics composed of either polymethylmethacrylate, ethylenevinyl alcohol, or cellulose diacetate materials. Protein Western Blot and SDS-PAGE coupled to mass spectrometry analysis were applied to highlight the carbonylated protein-binding characteristics of the different materials. We also investigated in vivo protein carbonylation and carboxy methyl lisine-modification in plasma obtained before and after a haemodialysis session.

Results

Our data underline a different capability on protein adsorption associated with the different properties of the filter materials, highlighting the central buffering and protective role of serum albumin. In particular, polymethylmethacrylate and cellulose diacetate showed, in vitro, the highest capacity of binding plasma proteins on the surface of the hollow fiber minidialyzers. Conclusions: The present study suggests that biomaterials used for fabrication of haemodialysis membrane may affect the carbonyl balance in chronic uremic patients.