CT protocol optimisation in PET/CT: a systematic review

PET/CT中CT方案优化:系统评价

阅读:1

Abstract

PURPOSE: Currently, no consistent guidelines for CT scans used within PET/CT examinations are available. This systematic review provides an up-to-date overview of studies to answer the following questions: What are the specific CT protocols used in PET/CT? What are the possible purposes of requiring a CT study within a PET/CT scan? Is the CT protocol obtained from a dosimetric optimisation study? MATERIALS AND METHOD: PubMed/MEDLINE, Cochrane Library, Embase and Scopus were systematically searched for relevant studies in accordance with the PRISMA statement. The literature search was conducted from January 2007 until June 2019. Data derived from studies were standardized in order to reduce possible biases, and they were divided into clinically homogeneous subgroups (adult, child or phantom). Subsequently, we divided the CT protocol intents into 3 types (anatomic localization only, attenuation correction only and diagnostic purpose). A narrative approach was used to summarise datasets and to investigate their heterogeneity (due to medical prescription methodology) and their combination in multiseries CT protocols. When weighted computed tomography dose index (CTDI(w)) was available, we calculated the volumetric computed tomography dose index (CTDI(vol)) using the pitch value to make the results uniform. Eventually, the correlation between protocol intents and CTDI(vol) values was obtained using a Kruskal-Wallis one-way ANOVA statistical test. RESULT: Starting from a total of 1440 retrieved records, twenty-four studies were eligible for inclusion in addition to two large multicentric works that we used to compare the results. We analyzed 87 CT protocols. There was a considerable range of variation in the acquisition parameters: tube current-time product revealed to have the most variable range, which was 10-300 mAs for adults and 10-80 mAs for paediatric patients. Seventy percent of datasets presented scans acquired with tube current modulation, 9% used fixed tube current and in 21% of them, this information was not available. Dependence between mean CTDI(vol) values and protocol intent was statistically significant (p = 0.002). As expected, in diagnostic protocols, there was a statistically significant difference between CTDI(vol) values of with and without contrast acquisitions (11.68 mGy vs 7.99 mGy, p = 0.009). In 13 out of 87 studies, the optimisation aim was not reported; in 2 papers, a clinical protocol was used; and in 11 works, a dose optimisation protocol was applied. CONCLUSIONS: According to this review, the dose optimisation in PET/CT exams depends heavily on the correct implementation of the CT protocol. In addition to this, considering the latest technology advances (i.e. iterative algorithms development), we suggest a periodic quality control audit to stay updated on new clinical utility modalities and to achieve a shared standardisation of clinical protocols. In conclusion, this study pointed out the necessity to better identify the specific CT protocol use within PET/CT scans, taking into account the continuous development of new technologies.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。