Image quality analysis of (44)Sc on two preclinical PET scanners: a comparison to (68)Ga

对两台临床前PET扫描仪上的(44)Sc进行图像质量分析:与(68)Ga的比较

阅读:2

Abstract

BACKGROUND: (44)Sc has been increasingly investigated as a potential alternative to (68)Ga in the development of tracers for positron emission tomography (PET). The lower mean positron energy of (44)Sc (0.63 MeV) compared to (68)Ga (0.83 MeV) can result in better spatial image resolutions. However, high-energy γ-rays (1157 keV) are emitted at high rates (99.9%) during (44)Sc decay, which can reduce image quality. Therefore, we investigated the impact of these physical properties and performed an unbiased performance evaluation of (44)Sc and (68)Ga with different imaging phantoms (image quality phantom, Derenzo phantom, and three-rod phantom) on two preclinical PET scanners (Mediso nanoScan PET/MRI, Siemens microPET Focus 120). RESULTS: Despite the presence of high-energy γ-rays in (44)Sc decay, a higher image resolution of small structures was observed with (44)Sc when compared to (68)Ga. Structures as small as 1.3 mm using the Mediso system, and as small as 1.0 mm using the Siemens system, could be visualized and analyzed by calculating full width at half maximum. Full widths at half maxima were similar for both isotopes. For image quality comparison, we calculated recovery coefficients in 1-5 mm rods and spillover ratios in either air, water, or bone-equivalent material (Teflon). Recovery coefficients for (44)Sc were significantly higher than those for (68)Ga. Despite the lower positron energy, (44)Sc-derived spillover ratio (SOR) values were similar or slightly higher to (68)Ga-derived SOR values. This may be attributed to the higher background caused by the additional γ-rays. On the Siemens system, an overestimation of scatter correction in the central part of the phantom was observed causing a virtual disappearance of spillover inside the three-rod phantom. CONCLUSION: Based on these findings, (44)Sc appears to be a suitable alternative to (68)Ga. The superior image resolution makes it an especially strong competitor in preclinical settings. The additional γ-emissions have a small impact on the imaging resolution but cause higher background noises and can effect an overestimation of scatter correction, depending on the PET system and phantom.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。