Investigation of post-therapeutic image-based thyroid dosimetry using quantitative SPECT/CT, iodine biokinetics, and the MIRD's voxel S values in Graves' disease

利用定量SPECT/CT、碘生物动力学和MIRD体素S值,研究格雷夫斯病治疗后基于影像的甲状腺剂量测定

阅读:1

Abstract

BACKGROUND: Before radioiodine therapy for Graves' disease, the estimated thyroid-absorbed dose is calculated based on various clinical parameters. However, the actual accumulation of iodine in the thyroid during radioiodine therapy is not determined. We validated the feasibility of post-therapeutic image-based thyroid dosimetry through quantitative single-photon emission computed tomography (SPECT) imaging and thyroid biokinetics and expanding the Medical Internal Radiation Dose Committee's (MIRD) voxel dosimetry guidelines. METHODS: Forty-three patients with Graves' disease who underwent radioiodine therapy were chosen as subjects for this retrospective analysis. We acquired patients' SPECT images 24 h after oral administration. SPECT images were quantified using system volume sensitivity to calculate time-integrated activity coefficients on a voxel basis. Absorbed dose was obtained by convolving MIRD guideline voxel S values with time-integrated activity coefficients. To determine accuracy, we compared the results obtained using the post-therapeutic image-based absorbed-dose method (D̅(image,PVC)) with absorbed doses calculated using the method described by the European Association of Nuclear Medicine (pre-therapeutic method; D(EANM)). RESULTS: Using image-based dosimetry as post-therapeutic dosimetry, we visualized the local accumulation and absorbed dose distribution of iodine in the thyroid. Furthermore, we determined a strong correlation (Pearson's correlation coefficient = 0.89) between both dosimetries, using the regression equation: D̅(image,PVC) = 0.94 × D(EANM) + 1.35. CONCLUSION: Post-therapeutic image-based doses absorbed in the thyroid resembled those of pre-therapeutic EANM method-based absorbed doses. Additionally, the post-therapeutic image-based method had the advantage of visualizing thyroid iodine distribution, thus determining local dose distributions at the time of treatment. From these points, we propose that post-therapeutic image-based dosimetry could provide an alternative to standard pre-therapeutic dosimetry to evaluate dose response.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。