NEMA NU 2-2007 performance characteristics of GE Signa integrated PET/MR for different PET isotopes

NEMA NU 2-2007 GE Signa 集成式 PET/MR 对不同 PET 同位素的性能特征

阅读:1

Abstract

BACKGROUND: Fully integrated PET/MR systems are being used frequently in clinical research and routine. National Electrical Manufacturers Association (NEMA) characterization of these systems is generally done with (18)F which is clinically the most relevant PET isotope. However, other PET isotopes, such as (68)Ga and (90)Y, are gaining clinical importance as they are of specific interest for oncological applications and for follow-up of (90)Y-based radionuclide therapy. These isotopes have a complex decay scheme with a variety of prompt gammas in coincidence. (68)Ga and (90)Y have higher positron energy and, because of the larger positron range, there may be interference with the magnetic field of the MR compared to (18)F. Therefore, it is relevant to determine the performance of PET/MR for these clinically relevant and commercially available isotopes. METHODS: NEMA NU 2-2007 performance measurements were performed for characterizing the spatial resolution, sensitivity, image quality, and the accuracy of attenuation and scatter corrections for (18)F, (68)Ga, and (90)Y. Scatter fraction and noise equivalent count rate (NECR) tests were performed using (18)F and (68)Ga. All phantom data were acquired on the GE Signa integrated PET/MR system, installed in UZ Leuven, Belgium. RESULTS: (18)F, (68)Ga, and (90)Y NEMA performance tests resulted in substantially different system characteristics. In comparison with (18)F, the spatial resolution is about 1 mm larger in the axial direction for (68)Ga and no significative effect was found for (90)Y. The impact of this lower resolution is also visible in the recovery coefficients of the smallest spheres of (68)Ga in image quality measurements, where clearly lower values are obtained. For (90)Y, the low number of counts leads to a large variability in the image quality measurements. The primary factor for the sensitivity change is the scale factor related to the positron emission fraction. There is also an impact on the peak NECR, which is lower for (68)Ga than for (18)F and appears at higher activities. CONCLUSIONS: The system performance of GE Signa integrated PET/MR was substantially different, in terms of NEMA spatial resolution, image quality, and NECR for (68)Ga and (90)Y compared to (18)F. But these differences are compensated by the PET/MR scanner technologies and reconstructions methods.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。