Intracorneal implantation of a misdirected foldable intraocular lens during phacoemulsification surgery: a case report

超声乳化术中误植入折叠式人工晶状体的角膜内病例报告

阅读:1

Abstract

A 59-year-old man presented with a unilateral blurring of vision in his left eye. His left eye's visual acuity was hand movements level. He underwent phacoemulsification surgery, and an intrastromal posterior chamber intraocular lens was implanted. The intrastromal intraocular lens was extracted and a new intraocular lens was implanted. Usinge the Snellen chart, the final best-corrected visual acuity was 20/40. With this case report, we wish to emphasize that a single stepwise clear corneal incision merged with wound-assisted intraocular lens injections can result in intraocular lens misdirection into the corneal stroma. As a result, while performing a misdirected intraocular lens removal, we recommend that the wound be carefully constructed.