Relevance of lesion size in navigator-triggered and free-breathing diffusion-weighted liver MRI

病灶大小在导航触发和自由呼吸弥散加权肝脏MRI中的相关性

阅读:1

Abstract

OBJECTIVES: The purpose of this study was to investigate the relevance of focal liver lesions (FLL) size for lesion detection comparing navigator triggering (TRIG) to free breathing (FB) liver Diffusion-weighted magnetic resonance imaging (DWI). MATERIALS AND METHOD: Patients with known or suspected FLL were prospectively (registry number 276_19 B) included from October to December 2019 in this study, out of which 32 had liver lesions. Echo planar spin-echo DWI data both with TRIG and FB were with approximately constant acquisition times acquired at 1.5 T. Lesions were segmented in the b = 800 s/mm² images in both the TRIG and FB images. The lesion size, location (liver segment), liver lesion visibility, as well as contrast-to-noise ratio (CNR) were recorded. The CNR was assessed with the Wilcoxon-Mann-Whitney test and the number of visible lesions with the Fisher test. RESULTS: Data from 43 patients (22 female) were analyzed. The mean patient age was 58 ± 14 years. A total of 885 FLL (N(total)) were segmented. Among these, 811 lesions (N(both)) were detected with TRIG and FB, 65 lesions exclusively with TRIG (N(TRIG_Only)), and nine exclusively in FB (N(FB_Only)). The largest additional lesion in TRIG/FB had a diameter of 10.4 mm/7.6 mm. The number of additional lesions detected with TRIG decreased with size. Among all lesions ≤ 4.7 mm, the relative number of additional lesions was 15.6%. Additional lesions were found in all liver segments with TRIG. In the left liver lobe, the relative proportion was 9.2%, and in the right liver lobe 5.4%. CNR and visibility were significantly higher in TRIG than in FB (p < 0.001). In relation to size, the difference is significant in terms of visibility and CNR for lesion diameters ≤ 8 mm. CONCLUSION: Respiration triggering can improve the detection of small liver lesions with diameters up to approx. 1 cm in the whole liver. KEY POINTS: Question Can respiration triggering (TRIG) improve the detection of small FLL compared to FB diffusion-weighted imaging? Findings Among 885 segmented FLL, TRIG was superior to FB for lesions smaller than 8 mm and had improved CNR and visibility. Clinical relevance Diffusion-weighted magnetic resonance imaging is used for the detection of focal liver lesions and image quality is influenced by breathing motion. Navigator triggering becomes more important for smaller lesions, and seems recommendable for the detection of small focal liver lesions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。