Sonographic evaluation of intravascular volume status: Can internal jugular or femoral vein collapsibility be used in the absence of IVC visualization?

超声评估血管内血容量状态:在无法观察到下腔静脉的情况下,能否利用颈内静脉或股静脉的塌陷性来评估血容量状态?

阅读:1

Abstract

INTRODUCTION: Inferior vena cava collapsibility index (IVC-CI) has been shown to correlate with both clinical and invasive assessment of intravascular volume status, but has important limitations such as the requirement for advanced sonographic skills, the degree of difficulty in obtaining those skills, and often challenging visualization of the IVC in the postoperative patient. The current study aims to explore the potential for using femoral (FV) or internal jugular (IJV) vein collapsibility as alternative sonographic options in the absence of adequate IVC visualization. METHODS: A prospective, observational study comparing IVC-CI and Fem- and/or IJV-CI was performed in two intensive care units (ICU) between January 2012 and April 2014. Concurrent M-mode measurements of IVC-CI and FV- and/or IJV-CI were collected during each sonographic session. Measurements of IVC were obtained using standard technique. IJV-CI and FV-CI were measured using high-frequency, linear array ultrasound probe placed in the corresponding anatomic areas. Paired data were analyzed using coefficient of correlation/determination and Bland-Altman determination of measurement bias. RESULTS: We performed paired ultrasound examination of IVC-IJV (n = 39) and IVC-FV (n = 22), in 40 patients (mean age 54.1; 40% women). Both FV-CI and IJV-CI scans took less time to complete than IVC-CI scans (both, P < 0.02). Correlations between IVC-CI/FV-CI (R(2) = 0.41) and IVC-CI/IJV-CI (R(2) = 0.38) were weak. There was a mean -3.5% measurement bias between IVC-CI and IJV-CI, with trend toward overestimation for IJV-CI with increasing collapsibility. In contrast, FV-CI underestimated collapsibility by approximately 3.8% across the measured collapsibility range. CONCLUSION: Despite small measurement biases, correlations between IVC-CI and FV-/IJV-CI are weak. These results indicate that IJ-CI and FV-CI should not be used as a primary intravascular volume assessment tool for clinical decision support in the ICU. The authors propose that IJV-CI and FV-CI be reserved for clinical scenarios where sonographic acquisition of both IVC-CI or subclavian collapsibility are not feasible, especially when trended over time. Sonographers should be aware that IJV-CI tends to overestimate collapsibility when compared to IVC-CI, and FV-CI tends to underestimates collapsibility relative to IVC-CI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。