Applied mechanics of the Puricelli osteotomy: a linear elastic analysis with the finite element method

Puricelli截骨术的应用力学:基于有限元法的线性弹性分析

阅读:1

Abstract

BACKGROUND: Surgical orthopedic treatment of the mandible depends on the development of techniques resulting in adequate healing processes. In a new technical and conceptual alternative recently introduced by Puricelli, osteotomy is performed in a more distal region, next to the mental foramen. The method results in an increased area of bone contact, resulting in larger sliding rates among bone segments. This work aimed to investigate the mechanical stability of the Puricelli osteotomy design. METHODS: Laboratory tests complied with an Applied Mechanics protocol, in which results from the Control group (without osteotomy) were compared with those from Test I (Obwegeser-Dal Pont osteotomy) and Test II (Puricelli osteotomy) groups. Mandible edentulous prototypes were scanned using computerized tomography, and digitalized images were used to build voxel-based finite element models. A new code was developed for solving the voxel-based finite elements equations, using a reconditioned conjugate gradients iterative solver. The Magnitude of Displacement and von Mises equivalent stress fields were compared among the three groups. RESULTS: In Test Group I, maximum stress was seen in the region of the rigid internal fixation plate, with value greater than those of Test II and Control groups. In Test Group II, maximum stress was in the same region as in Control group, but was lower. The results of this comparative study using the Finite Element Analysis suggest that Puricelli osteotomy presents better mechanical stability than the original Obwegeser-Dal Pont technique. The increased area of the proximal segment and consequent decrease of the size of lever arm applied to the mandible in the modified technique yielded lower stress values, and consequently greater stability of the bone segments. CONCLUSION: This work showed that Puricelli osteotomy of the mandible results in greater mechanical stability when compared to the original technique introduced by Obwegeser-Dal Pont. The increased area of the proximal segment and consequent decrease of the size of lever arm applied to the mandible in the modified technique yield lower stress values and displacements, and consequently greater stability of the bone segments.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。