Role of cerebroventricular size and surgical placement in modulating catheter flow distribution

脑室大小和手术位置在调节导管血流分布中的作用

阅读:1

Abstract

Ventricular shunt catheters are the standard of care for managing hydrocephalus, yet 40% of implanted catheters fail within two years of implantation, mainly due to proximal catheter obstruction. Prior literature suggests that cerebrospinal fluid (CSF) preferentially enters the ventricular catheter’s holes farthest from the catheter tip, where obstruction has been thought to frequently occur. However, previous studies have relied on simplified geometries and idealized catheter positioning, limiting the ability to capture patient-specific anatomical variability. Segmental flow distribution in ventricular catheters was analyzed using ventricular models derived from pediatric patients with hydrocephalus. Two pediatric shunted patients and one pediatric externalized patient with varied sizes, ranging from enlarged (FOHR: 0.45), moderate (0.30), and small (0.29), were segmented from MRI scans and reconstructed into closed-volume 3D models. We simulated the insertion of a 4-row, 4-hole ventricular catheter using frontal, parietal, and occipital surgical approaches. A choroid plexus mimic modeled from confocal microscopy was attached to the ventricular system for inlet flow, and a constant flow rate of 0.35 mL/min was applied to simulate CSF flow inside the ventricular domain. Steady-state, laminar 3D computational fluid dynamics simulations were performed to quantify mass flow into each catheter drainage segment. Occipital placement consistently concentrated flow (> 81%) in the fourth (most distal) segment across all ventricular sizes. In contrast, frontal and parietal approaches showed variable flow distributions dependent on ventricular morphology. In the moderate ventricle, parenchymal contact obstructed distal holes, redirecting flow proximally (Segments 1–2: >99%). Segmental flow distribution was influenced by drainage hole patency, ventricular morphology, and catheter orientation. Altogether, these data suggest that anatomical or approach dependent shifts result in specific tissue contact changes and therefore change in flow distribution. A larger sample scale study is needed to understand variability resulting from heterogeneous catheter placement in varying ventricular morphologies. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12987-026-00786-6.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。