Imaging blood to periarterial CSF flow coupling using 4D flow MRI and an ultra-high-performance head-only gradient system

利用4D流磁共振成像和超高性能头部专用梯度系统对血液与动脉周围脑脊液流动耦合进行成像

阅读:1

Abstract

BACKGROUND: Periarterial cerebrospinal fluid (CSF) flow has been hypothesized to contribute to brain waste clearance but is poorly understood. Animal studies suggest arterial pulsatility drives perivascular CSF in the direction of cerebral arterial blood flow (CBF), but human validation has relied on MRI approaches that do not inform on flow-directionality. Here, we use a high-performance gradient system enabling low velocity encoding (Venc) 4D flow MRI, to characterize cardiac-driven periarterial CSF flow and CBF-to-CSF flow coupling. METHODS: Healthy participants (N = 10) underwent high resolution (0.8 mm isotropic) 4D flow MRI of blood (Venc = 120 cm/s) and CSF (Venc = 1.0 cm/s) on a 3.0T head-only system (MAGNUS, GE Healthcare; Gmax = 300mT/m, Smax = 750T/m/s). Images were reconstructed using local low rank (LLR) constrained parallel imaging and background field corrected using iterative, complex domain fitting. Luminal blood and associated periarterial CSF waveforms were extracted along the left and right anterior (ACA A1), middle (MCA M1 and M2), and posterior (PCA P2) cerebral arteries using a centerline approach, and characterized individually by amplitude and stroke volume and jointly by coupling coefficients from maximum cross-correlation ([Formula: see text]) and time-lags. RESULTS: For low Venc 4D flow MRI, MAGNUS dramatically reduced the echo time and temporal resolution compared to whole-body systems. CBF and CSF measurements were successful in 61/80 locations (up to 8 per participant) with 19 measurements excluded due to velocity aliasing and/or poor local quality of the flow data. Inverse (anti-correlated) CBF-to-CSF coupling ([Formula: see text]) was observed for most segments (56/61), with strong coupling observed for all vessels, including M1 (-0.85 ± 0.06), A1 (-0.80 ± 0.12), P2 (-0.79 ± 0.08), and M2 (-0.78 ± 0.08). Further, CBF preceded CSF for most (43/56) segments, with short CBF-to-CSF lags in A1 (5.30 ± 64 ms) and P2 (4.13 ± 63 ms), higher in M1 (43 ± 39 ms), and highest in M2 (115 ± 39 ms). CBF and CSF flow metrics were also correlated in terms of flow rate amplitude (r = 0.40, p = 0.015) and stroke volume (r = 0.56, p < 0.001). CONCLUSIONS: High-performance gradient systems facilitate 4D flow imaging of very slow CSF. Joint analysis of CBF and periarterial CSF allowed assessment of CBF-to-CSF dynamics coupling. For most vessels, an inverse coupling and a positive time-lag was found from CBF to periarterial CSF, suggesting that the systolic arterial expansion drives CSF backwards and inwards again during diastolic relaxation. The proposed approach can be used to improve our understanding of CBF and CSF dynamics in aging and dementia. CLINICAL TRIAL NUMBER: Not applicable.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。