Evaluation of diurnal and postural intracranial pressure employing telemetric monitoring in idiopathic intracranial hypertension

利用遥测监测评估特发性颅内高压患者的昼夜和体位性颅内压

阅读:1

Abstract

OBJECTIVES: Intracranial pressure (ICP) has been thought to vary diurnally. This study evaluates diurnal ICP measurements and quantifies changes in ICP occurring with changes in body posture in active idiopathic intracranial hypertension (IIH). METHODS: This prospective observational study utilized telemetric ICP monitoring in people with active IIH. Participants had the Raumedic p-Tel ICP intraparenchymal device (Raumedic, Hembrechts, Germany) surgically inserted. Changes in ICP in the supine position were evaluated. Then, the ICP was measured in the standing, sitting, supine, left lateral decubitus positions and with coughing and bending. Ultimately, changes in ICP over the course of 24 h were recorded. ISRCTN registration number 12678718. RESULTS: 15 women were included, mean (standard deviation) age 29.5 (9.5) years, body mass index 38.1 (6.2) kg/m(2), and baseline mean ICP of 21.2 (4.8) mmHg (equivalent to 28.8 (6.5) cmCSF). Mean ICP rose with the duration in the supine position 1.2 (3.3) mmHg over 5-minutes (p = 0.175), 3.5 (2.8) mmHg over 30-minutes (p = 0.0002) and by a further 2.1 (2.2) mmHg over 3 h (p = 0.042). Mean ICP decreased by 51% when moving from the supine position to standing (21.2 (4.8) mmHg to 10.3 (3.7) mmHg respectively, p = 0.0001). Mean ICP increased by 13% moving from supine to the left lateral decubitus position (21.2 (4.8) mmHg to 24.0 (3.8) mmHg, p = 0.028). There was no significant difference in ICP measurements at any point during the daytime, or between 5-minute standing or supine recordings and prolonged ambulatory daytime and end of night supine recordings respectively. ICP, following an initial drop, increased progressively in conjunction with lying supine position from 23:00 h to 07:00 h by 34% (5.2 (1.9) mmHg, p = 0.026). CONCLUSION: This analysis demonstrated that ICP does not appear to have a diurnal variation in IIH, but varies by position and duration in the supine position. ICP rose at night whilst the patient was continuously supine. Furthermore, brief standing and supine ICP measures in the day predicted daytime prolonged ambulatory measures and end of night peak ICP respectively. This knowledge gives reassurance that ICP can be accurately measured and compared at any time of day in an ambulant IIH patient. These are useful findings to inform clinical measurements and in the interpretation of ICP analyses in IIH. TRIAL REGISTRATION: ISTCRN (12678718).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。