Risk for life-threatening arrhythmia in newly diagnosed peripartum cardiomyopathy with low ejection fraction: a German multi-centre analysis

一项德国多中心分析显示,新诊断的低射血分数围产期心肌病患者发生危及生命的心律失常的风险较高。

阅读:1

Abstract

INTRODUCTION: Peripartum cardiomyopathy (PPCM) is a rare cardiomyopathy characterized by an acute reduction in left ventricular ejection fraction (LVEF). Sudden deaths during the course of PPCM are reported to be elevated, the underlying mechanisms remains unknown. The aim of the present multi-centre study was to evaluate the arrhythmia burden in a multi-centre approach in patients with PPCM using a wearable cardioverter/defibrillator (WCD). METHODS AND RESULTS: Forty-nine patients from 16 German centres with newly diagnosed PPCM and LVEF ≤35% receiving a WCD were included in this retrospective analysis. Mean follow-up was 15 ± 10 months. At diagnosis, mean age was 33 ± 5 years, parity was 2.1 ± 1.6, LVEF was 21 ± 7%, NYHA functional class was 3.4 ± 0.7. Mean wear time was 120 ± 106 days, mean wear time per day was 21.4 ± 3.3 h. Six (12%) patients presented eight ventricular tachyarrhythmias during WCD period: five episodes of VF, two sustained ventricular tachycardia (VT) and one non-sustained VT occurred. CONCLUSION: This multicentre study underpins the elevated risk for ventricular tachyarrhythmias in patients with newly diagnosed PPCM and reduced LVEF. A WCD should be considered for 3-6 months in these patients to prevent sudden cardiac death from ventricular tachyarrhythmias.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。