Trisodium citrate 4% versus heparin as a catheter lock for non-tunneled hemodialysis catheters in critically ill patients: a multicenter, randomized clinical trial

4%柠檬酸三钠与肝素作为危重患者非隧道式血液透析导管封管液的比较:一项多中心随机临床试验

阅读:1

Abstract

BACKGROUND: Non-tunneled hemodialysis catheters are currently used for critically ill patients with acute kidney injury requiring extracorporeal renal replacement therapy. Strategies to prevent catheter dysfunction and infection with catheter locks remain controversial. METHODS: In a multicenter, randomized, controlled, double-blind trial, we compared two strategies for catheter locking of non-tunneled hemodialysis catheters, namely trisodium citrate at 4% (intervention group) versus unfractionated heparin (control group), in patients aged 18 years or older admitted to the intensive care unit and in whom a first non-tunneled hemodialysis catheter was to be inserted by the jugular or femoral vein. The primary endpoint was length of event-free survival of the first non-tunneled hemodialysis catheter. Secondary endpoints were: rate of fibrinolysis, incidence of catheter dysfunction and incidence of catheter-related bloodstream infection (CRBSI), all per 1000 catheter-days; number of hemorrhagic events requiring transfusion, length of stay in intensive care and in hospital; 28-day mortality. RESULTS: Overall, 396 randomized patients completed the trial: 199 in the citrate group and 197 in the heparin group. There was no significant difference in baseline characteristics between groups. The duration of event-free survival of the first non-tunneled hemodialysis catheter was not significantly different between groups: 7 days (IQR 3-10) in the citrate group and 5 days (IQR 3-11) in the heparin group (p = 0.51). Rates of catheter thrombosis, CRBSI, and adverse events were not statistically different between groups. CONCLUSIONS: In critically ill patients, there was no significant difference in the duration of event-free survival of the first non-tunneled hemodialysis catheter between trisodium citrate 4% and heparin as a locking solution. Catheter thrombosis, catheter-related infection, and adverse events were not statistically different between the two groups. Trial registration Registered with Clinicaltrials.gov under the number NCT01962116. Registered 14 October 2013.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。