Bacteriostatic effects of nanometer silver disinfectant on the biofilms in dental unit water lines

纳米银消毒剂对牙科治疗台水管生物膜的抑菌作用

阅读:1

Abstract

BACKGROUND/PURPOSE: Dental unit water lines (DUWLs) may be contaminated by aerobic bacteria in clinical settings and comprehensive disinfecting methods should be considered without delay. Herein, this study aims to investigate the timeliness and dynamic bacteriostatic effects of different forms of nanometer silver (NMS) disinfectant on bio-film in DUWLs. MATERIALS AND METHODS: Bacterial DUWLs samples were respectively treated with different NMS forms, including liquid phase and solid phase at the concentrations of 0.25%, 0.5%, 1% and 2% and their bacteriostatic effects were observed at the 1st, 4th, 7th, 14th, (28th) day. RESULTS: The bacteriostatic effects of liquid phase NMS at all concentrations were unsatisfactory and the bacteriostatic rate was only 20% at the 1st day. However, there appeared massive bacteria growth at the 4th, 7th, 14th, 28th day. Comparatively, no bacteria growth was found at the 1st, 4th, 7th, 14th, (28th) day after sterilizing with different concentrations of solid phase NMS and the bacteriostatic rate was 100%. CONCLUSION: Microbial contamination in DUWLs can be disinfected by different NMS forms, among which solid phase NMS is more bactericidal against bacteria bio-films, demonstrating significant roles of solid phase NMS in preventing DUWL contamination.