Optimized dual-time-window protocols for quantitative [(18)F]flutemetamol and [(18)F]florbetaben PET studies

针对定量[(18)F]氟他莫和[(18)F]氟贝他苯PET研究的优化双时间窗方案

阅读:1

Abstract

BACKGROUND: A long dynamic scanning protocol may be required to accurately measure longitudinal changes in amyloid load. However, such a protocol results in a lower patient comfort and scanning efficiency compared to static scans. A compromise can be achieved by implementing dual-time-window protocols. This study aimed to optimize these protocols for quantitative [(18)F]flutemetamol and [(18)F]florbetaben studies. METHODS: Rate constants for subjects across the Alzheimer's disease spectrum (i.e., non-displaceable binding potential (BP(ND)) in the range 0.02-0.77 and 0.02-1.04 for [(18)F]flutemetamol and [(18)F]florbetaben, respectively) were established based on clinical [(18)F]flutemetamol (N = 6) and [(18)F]florbetaben (N = 20) data, and used to simulate tissue time-activity curves (TACs) of 110 min using a reference tissue and plasma input model. Next, noise was added (N = 50) and data points corresponding to different intervals were removed from the TACs, ranging from 0 (i.e., 90-90 = full-kinetic curve) to 80 (i.e., 10-90) minutes, creating a dual-time-window. Resulting TACs were fitted using the simplified reference tissue method (SRTM) to estimate the BP(ND), outliers (≥ 1.5 × BP(ND) max) were removed and the bias was assessed using the distribution volume ratio (DVR = BP(ND) + 1). To this end, acceptability curves, which display the fraction of data below a certain bias threshold, were generated and the area under those curves were calculated. RESULTS: [(18)F]Flutemetamol and [(18)F]florbetaben data demonstrated an increased bias in amyloid estimate for larger intervals and higher noise levels. An acceptable bias (≤ 3.1%) in DVR could be obtained with all except the 10-90 and 20-90-min intervals. Furthermore, a reduced fraction of acceptable data and most outliers were present for these two largest intervals (maximum percentage outliers 48 and 32 for [(18)F]flutemetamol and [(18)F]florbetaben, respectively). CONCLUSIONS: The length of the interval inversely correlates with the accuracy of the BP(ND) estimates. Consequently, a dual-time-window protocol of 0-30 and 90-110 min (=maximum of 60 min interval) allows for accurate estimation of BP(ND) values for both tracers. [(18)F]flutemetamol: EudraCT 2007-000784-19, registered 8 February 2007, [(18)F]florbetaben: EudraCT 2006-003882-15, registered 2006.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。