Detection of Schistosoma mansoni DNA using polymerase chain reaction from serum and dried blood spot card samples of an adult population in North-western Tanzania

利用聚合酶链式反应检测坦桑尼亚西北部成年人群血清和干血斑卡片样本中的曼氏血吸虫DNA

阅读:1

Abstract

BACKGROUND: Real-time polymerase chain reaction (PCR) is a sensitive and specific method for diagnosing schistosomiasis. However, this method should be performed in a laboratory, usually located distant from the sample collection site. Therefore, it is important to have fast sampling preservation methods, which allow simple transport prior to DNA extraction and amplification. The aim of this study was to verify if blood samples applied to filter paper are suitable for analysis of Schistosoma mansoni DNA by real-time PCR. METHODS: A cross-sectional study was conducted among 100 study participants aged 17 to 70 years in a fishing village on the southern shore of Lake Victoria, Tanzania. Serum samples and ethylenediaminetetraacetic acid (EDTA)-anticoagulated whole blood for preparation of dried blood spots (DBS) were collected to test for Schistosoma mansoni infection by real-time PCR. A combined diagnostic reference of positive results of serum-based real-time PCR and the Kato-Katz (KK) method was used for analysis. Sensitivity and negative predictive value (NPV) were calculated. The Wilcoxon signed-rank test was chosen to compare the mean cycle threshold (Ct) values from serum and DBS. RESULTS: According to the reference, 92.5% S. mansoni positive samples were determined. The serum-based real-time PCR performed excellently with 95.4% sensitivity, whereas the DBS-based real-time PCR showed a low sensitivity (45.4%). The Ct-values were significantly higher in DBS (median: 37.3) than in serum samples (median: 27.5, P < 0.001), reflecting a lower parasite-specific DNA load on the filter cards. With increasing egg counts, an increase in sensitivity was observed for all methods. The POC-CCA test and the serum-based real-time PCR showed a sensitivity of 100% for medium and severe infections. The DBS real-time PCR showed a sensitivity of only 85.7% even for severe infections. CONCLUSIONS: DBS-based real-time PCR did not provide good results in our study and therefore should not be recommended or must be tested concerning temperature of storage, storage duration, use of different filter papers and extraction methods before it is used in future studies. In contrast, our results showed that the POC-CCA test is a sensitive and precise test for detecting S. mansoni infections .

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。