Electro-analytical sensing of anti-hypotensive agents: application to dosage forms and human urine

抗低血压药物的电分析传感:在剂型和人尿中的应用

阅读:2

Abstract

A new and valid method was developed for the quantitative voltammetric analysis of midodrine hydrochloride (MID) in pharmaceutical tablets (Midodrine) and biological samples. The method is based on electro-oxidation of MID supported by both disposable pencil electrode (PE) and glassy carbon electrode (GCE). The analysis was carried out using cyclic voltammetry, differential pulse voltammetry (DPV), and square wave voltammetry (SWV) techniques. The proposed analytical method was validated according to ICH guidelines. MID was successively assayed at concentration ranges of 1.15-6.55 and 0.58-3.05 μg mL(-1) at PE. Also, MID was successively assayed at concentration ranges of 1.15-5.28 and 2.86-27.6 μg mL(-1) at GCE for DPV and SWV methods, respectively. The proposed method was successfully used for the analysis of MID in its dosage form and human urine with good recoveries of 99.66 ± 0.33, 99.8 ± 0.45 at PE and 99.8 ± 0.25, 98.7 ± 1.27 at GCE for the DPV and SWV methods, respectively. The suggested method could be applied to the studied drug in the quality control lab as well as in its pharmacokinetic studies.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。