Study on the Effect of Micro-Force Perturbations and Temperature Fluctuation on Interferometer for the Taiji Program

微力扰动及温度波动对太极拳干涉仪的影响研究

阅读:7
作者:Juan Wang, He-Shan Liu, Chao Yang, Ke-Qi Qi, Zi-Ren Luo, Ran Yang

Abstract

To increase the interferometric measurement resolution in the Taiji program, we present a noise suppression method in this paper. Taking the specific micro-force perturbation and temperature fluctuation in the Taiji-1 interferometer as an example, we set up and experimentally verified the corresponding transfer function to quantify the effect of both noise sources on the interferometric results. Consistent results were obtained between the numerical and experimental results for the transfer function. It is instructive to eliminate the micro-force perturbations and temperature fluctuations during on-orbit interferometric measurement for as long as the acquisition of the force or temperature distribution of related surfaces and the corresponding transfer functions. This indicates that the method can be used for noise sensing and more in the field of noise elimination and measurement resolution improvement for future Taiji program interferometers.