Real-Time IVUS Guided (RTIG) Ostial Stenting: A Step-by-Step Guide

实时血管内超声引导(RTIG)开口支架置入术:分步指南

阅读:2

Abstract

OBJECTIVE: Ostial coronary lesions can be challenging to manage and have higher rates of target lesion failure. We describe the novel technique of real-time intravascular ultrasound (IVUS)-guided stenting to optimize ostial stent placement. KEY STEPS: The key steps are: 1) Wire the target vessel and side branch, and prepare the lesion based on IVUS appearances. 2) Deliver the stent in beyond the target vessel lesion. 3) Pass the IVUS catheter into the side branch. 4) Withdraw the stent to a near-ostial position angiographically. 5) Withdraw the IVUS transducer to where the ostium is visible. 6) Deploy the stent. 7) Withdraw the IVUS catheter first. 8) Postdilate the stent. 9) Take a final IVUS run and angiogram. POTENTIAL PITFALLS: The technique requires at least a 7-F guide catheter and a 5-F IVUS catheter. The main learning curve is understanding the IVUS appearances of the stent delivery system. TAKE-HOME MESSAGE: Real-time IVUS guidance is an effective and teachable technique to allow accurate placement of ostial side branch stents.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。