Performance of a recombinant fusion protein linking coagulation factor IX with recombinant albumin in one-stage clotting assays

重组融合蛋白(凝血因子IX与重组白蛋白连接)在单阶段凝血试验中的性能

阅读:1

Abstract

Essentials Performance of the one-stage clotting (OSC) assay varies with the clotting activator used. Recombinant FIX-albumin fusion protein (rIX-FP) was reliably monitored with most OSC reagents. rIX-FP shows comparable reagent-dependent variability to other rFIX products in the OSC assay. Actin(®) FS and kaolin-based reagents underestimated rIX-FP activity by around 50% in the OSC assay. SUMMARY: Background Measuring factor IX activity (FIX:C) with one-stage clotting (OSC) assays, based on the activated partial thromboplastin time (APTT), is the current mainstay of diagnostic techniques for hemophilia B. Assessing the performance of new recombinant FIX (rFIX) products in OSC assays is essential, as APTT reagents from different manufacturers yield different potency estimates for rFIX. Objectives To evaluate the extent to which choice of reagent composition influences rFIX potency measurements of recombinant FIX-albumin fusion protein (rIX-FP, IDELVION) activity in OSC assays. Methods rIX-FP was added to FIX-deficient plasma, and FIX:C was assessed centrally and locally in a multicenter international field study with a variety of commercial OSC APTT reagents. Paired sample analysis of clinical samples was performed to compare values of FIX:C from local and central laboratories. In-house bioanalytical investigations with spiked samples were conducted to compare the APTT-reagent dependent variability of rIX-FP with unmodified rFIX and rFIX Fc fusion protein (rFIXFc). Results Central and local assessments of FIX:C from 10 countries and 21 participating centers showed comparable results to those from the central laboratory across the majority of 18 different APTT reagents from both clinical and spiked samples. There was a consistent underestimation of rIX-FP activity of ≈ 50% with OSC assays using Actin FS or kaolin-based APTT reagents. In the bioanalytical study, rIX-FP showed comparable variability in OSC assays to unmodified rFIX and rFIXFc. Conclusions rIX-FP activity can be accurately measured by the use of OSC assays with the majority of commercial reagents. Actin FS or kaolin-based reagents will probably lead to a 50% underestimation of activity.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。