Abstract

The airway pressure 100 msec after the onset of an inspiratory effort against a closed airway (P100, occlusion pressure) is theoretically a more accurate index of respiratory neuron motor output than ventilation. Occlusion pressure and ventilation responses to hypercapnia were compared in repeated trials in 10 normal subjects while in the seated and supine positions. During progressive hypercapnia changes in P100 were also compared to changes in tidal volume and inspiratory airflow. These studies show that occlusion pressure increases linearly with hypercapnia in both sitting and supine subjects. Changing from the seated to the supine position, or vice versa, had no significant effect on either ventilation or occlusion pressure responses to CO2. Correlations between P100 and ventilation or airflow rate were significantly higher than correlations between P100 and tidal volume or breathing frequency. Intermittent random airway occlusion had no effect on either ventilation or pattern of breathing during hypercapnia. Occlusion pressure responses were no less variable than ventilation responses in groups of subjects whether studied seated or supine. However, maintenance of a constant moderate breathing frequency (20 breaths per minute) reduced the interindividual variability in ventilation and occlusion pressure responses to hypercapnia.