Detection of a numeric value predictive of increased dose to left anterior descending coronary artery (LAD) in radiotherapy of breast cancer

检测预测乳腺癌放射治疗中左前降支冠状动脉(LAD)剂量增加的数值

阅读:2

Abstract

PURPOSE: We have evaluated thoracic conformation of patients in order to derive a numeric value predictive of an increased dose to left anterior descending coronary artery (LAD), critical structure for the development of late radio induced cardiac morbidity. METHODS: We have evaluated 91 patients (36-88 years) affected by breast cancer stage I-II (Tis-T1-2 N0-1), undergoing adjuvant radiotherapy with conventional fractionation. For each patient on CT images was measured the distance between the back face of the sternum (manubrium) and the anterior face of body of the corresponding vertebra (a), and the distance measured on the line at 45° between the vertebral body of the same vertebra and the back face of the rib corresponding (b). The a/b ratio showed values between 0.626 and 1.123. We used the median value (0.821) as cut-off to divide the patients in two groups. We calculated in both groups: Volume (Vol) heart, Vol LAD with an expansion of 0.6 mm; Dmean LAD (Gy); Dmax LAD (Gy); V10-V20-V30 (%) LAD and we correlated these values with parametric and non-parametric tests. RESULTS: The Pearson test has showed a statistically significant correlation between Vol breast and V10, V20, V30 with borderline significance (p = 0.006; p = 0.02; p = 0.05). The data were confirmed by testing non-parametric Kendall (tau = 0.004; tau = 0.015; tau = 0.016) and Spearman (rho = 0.003; rho = 0.016; rho = 0.015). We conducted categorizing into quartiles of breast volume and evaluated the correlation with a/b. We have found a significative correlation (p = 0.01) between small Vol breast (≤660.23 cc) and a/b < 0.0821 and greater Vol breast (>660.23 cc) with a/b > 0.0821. From the evaluation of the distribution of V10 in the two groups taking account of the Dmean ≤5 or >5 significance was found with a/b; Chi square 0.009 (0.01). Values ≤5 were observed in women with a/b < 0.0821. Values >5 in women with a/b > 0.0821. CONCLUSIONS: The geometric conformity of chest thorax considering a/b and the value of 0.0821 can reveals an important parameter in the selection of patients suitable for radiation therapy on left breast in order to evaluate the risk of late cardiac events. This consideration during treatment planning can change the technique or the set-up allowing the development of a customized plan.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。