Percutaneous discography: comparison of low-dose CT, fluoroscopy and MRI in the diagnosis of lumbar disc disruption

经皮椎间盘造影术:低剂量CT、透视和MRI在腰椎间盘突出诊断中的比较

阅读:1

Abstract

AIM: To compare the diagnostic accuracy of low-dose computed tomography (CT), magnetic resonance imaging (MRI) and fluoroscopy in percutaneous discography in patients scheduled for lumbar spondylodesis. MATERIAL AND METHODS: Within a prospective pilot study, 18 disc segments of 11 patients with radicular or pseudoradicular pain prior to anteroposterior spondylodesis were evaluated. After injection of a mixture of non-ionic iodine-containing contrast agent and gadolinium-based contrast medium into the disc spaces, all patients underwent conventional fluoroscopy, as well as low-dose CT and MRI. The occurrence of memory pain during contrast injection was recorded. CT, MRI and fluoroscopic images were analyzed independently by two readers blinded to the clinical findings. RESULTS: There was 100% agreement between CT and MRI discography in the detection, localization and grading of degenerative changes. In contrast, conventional fluoroscopy identified only 9 of the 12 abnormal segments. Memory pain following puncture was identified in 3 of the 12 affected segments. SUMMARY: Low-dose CT and MRI discography have a similar accuracy in the assessment of disc disruption and they are superior to fluoroscopic discography.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。